8.14 Diagnostic Tools
8.14.2 Easy FFT
Applicable Tools
The following table lists the tools that you can use to perform EasyFFT and the applicable tool
functions.
Digital Operator
SigmaWin+
Operating Procedure
Use the following procedure for Easy FFT.
1.
Select Setup - EasyFFT from the menu bar of the Main Window of the SigmaWin+.
The EasyFFT Dialog Box will be displayed.
Click the Cancel Button to cancel Easy FFT. You will return to the main window.
2.
Click the OK Button.
Another EasyFFT Dialog Box will be displayed.
3.
Click the Servo ON Button.
8-94
Tool
Function
Fn206
Setup - Easy FFT
Operating Procedure Reference
Σ-7-Series Servo Drive Digital Operator Operating Manual
(Manual No.: SIEP S800001 33)
Operating Procedure on page 8-94