Control Panel Assembly and Board (WorkCentre 3315/3325)
PL9.1.2, PL9.1.2.13, and PL10.1.2, PL10.1.2.7
1.
Remove 2 screws located under the front lip of the Control Panel (silver, flanged, tapping, 10 mm).
2.
Turn up the Control Panel.
3.
Disconnect CN1 and CN2 and remove the Control Panel Assembly.
CN1
Xerox Internal Use Only
Phaser 3320 and WorkCentre 3315/3325
Service Parts Disassembly
s3320-167
CN2
s3320-169
4-59