5. Optionally, rename the ES8508 in the Device Name field for a PortVision DX friendly name. The default
name displays as Device and the last three sets of hex numbers from the MAC address.
Note: The MAC address and Device Status fields are automatically populated and you cannot change
these values.
6. Optionally, enter the serial number, which is on a label on the ES8508.
7. Select DHCP IP or Static IP for the IP Mode.
If you select DHCP IP, go to
If you select Static IP:
-
Enter a unique IP address as required for your site.
-
Enter a valid Subnet Mask value for your network.
-
Enter a valid Default Gateway value for your network.
8. Optionally, select the Network Topology type, which is an informational field.
9. Click Apply Changes to update the network information on the ES8508.
Note: If you are deploying multiple ES8508 switches that share common values, you can save the
configuration file and load that configuration onto other ES8508 switches. See
Files
on Page 29 for more information.
10. Click Close to exit the Properties window.
11. You should verify that you have the latest firmware loaded on the ES8508 because a newer version
typically includes feature enhancements and bug fixes. Refer to
24 and if necessary,
12. If you have the latest firmware, you can begin feature configuration, see one of these sections:
Configuration Using the Web User Interface
Configuration Using the Command Line Interface (CLI)
Right-click the ES8508 in the Device List pane and click Webpage in the popup menu.
Note: The default User Name and Password are both admin.
RocketLinx ES8508 Series User Guide: 2000575 Rev. A
Step
8.
Uploading the Latest Firmware or Bootloader
Checking the Firmware Version
on Page 25.
on Page 35
on Page 131
Using PortVision DX
Using Configuration
Configuring the Network Settings - 23
on Page