ModBus TCP /IP Support
Word Address
0x0010
0x0010
0x0020
0x00A0
0x0120
0x01A0
0x01C0
0x01C2 to 0x01FF
0x0200
0x0202
0x0204
0x0206
0x0208
204 - Modbus TCP Register Table
Data Type
Product Name = "ES8508F-M"
Word 0 Hi byte = 'E'
Word 0 Lo byte = 'S'
Word 1 Hi byte = '8'
Word 1 Lo byte = '5'
16 words
Word 2 Hi byte = '0'
Word 2 Lo byte = '8'
Word 3 Hi byte = 'F'
Word 3 Lo byte = '-'
Word 4 Hi byte = 'M'
Word 4 Lo byte = '\0'
(other words = 0)
Product Name = "ES8508F-S"
Word 0 Hi byte = 'E'
Word 0 Lo byte = 'S'
Word 1 Hi byte = '8'
Word 1 Lo byte = '5'
16 words
Word 2 Hi byte = '0'
Word 2 Lo byte = '8'
Word 3 Hi byte = 'F'
Word 3 Lo byte = '-'
Word 4 Hi byte = 'S'
Word 4 Lo byte = '\0'
(other words = 0)
128 words
SNMP system name (string)
128 words
SNMP system location (string)
128 words
SNMP system contact (string)
32 words
SNMP system OID (string)
2 words
System uptime (unsigned long)
60 words
Reserved address space
2 words
Hardware version
2 words
S/N information
2 words
CPLD version
2 words
Bootloader version
Firmware Version
Word 0 Hi byte = major
2 words
Word 0 Lo byte = minor
Word 1 Hi byte = reserved
Word 1 Lo byte = reserved
Description
RocketLinx ES8508 Series User Guide: 2000575 Rev. A