Connect the Fiber Port (ES8508F)

Connect the fiber port to another fiber Ethernet device using the following diagram. An improper connection
will cause the fiber port to not work properly. The fiber port is a standard or square connector (SC). Make sure
that the fiber mode of the cable matches the fiber mode of the ES8508F (Single-Mode or Multi-Mode).
The fiber connector is a standard connector or square connector (SC).
Mode
Cable Type Wavelength
50/125um
Multi
62.5/125um
Single 8-10/125um
Note: In the IEEE standard, it suggests the available transmission distance is 2KM for 62.5/125um fiber
optical cable in 1310nm wave length. Actually, the attenuation of Multi-Mode 62.5/125um optical fiber
cable is 1.5dBm/km and the maximum link distance can up to 4 to 5km.
IEEE organization recommends maximum optical fiber cable distances as defined in the following table.
Standard
10BASE-FL
100BASE-FX 100
100BASE-SX 100
RocketLinx ES8508 Series User Guide: 2000575 Rev. A
This is a Class 1 Laser/LED product.
Do not stare into the Laser/LED beam.
Caution
Transmit
Power
-20dBm to
1310nm
-14dBm
-15dBm to
1310nm
-8dBm
Data Rate
(Mbps)
850nm, 50/125um or 62.5/
10
125um
Multi-Mode optical fiber cable
1310nm, 50/125um or 62.5/
125um
Multi-Mode optical fiber cable
850nm, 50/125um or 62.5/
125um
Multi-Mode optical fiber cable
Receive
Sensitivity
-31dBm to
11dBm
0dBm
-34dBm to
19dBm
-8dBm
Cable Type
Hardware Installation
Link
Distance (km)
Budget
2km
Note (below)
30km
IEEE Standard
Distance
2km
2km
300m