GENERAL.
The purpose of this chapter is to give supplemental information for the servicing of the oxygen systems.
Major repairs to the affected system and cylinder should be accomplished by an approved shop.
When refilling any oxygen cylinder make sure to use only aviation breathing oxygen as specified in MIL-
O-27210C. The moisture content of aviation breathing oxygen cannot exceed 0.005 milligrams of water vapor
per liter of gas at a temperature of 70°F and a pressure of 29.92 inches of mercury.
DESCRIPTION AND OPERATION. (Refer to Figures 35-1 and 35-2.)
A fixed and/or portable oxygen system is available on this aircraft. Scott Aviation manufactures the major
components for these systems and should be contacted along with Piper Customer Services for any further
information not covered herein. For specific parts information refer to the Piper Parts Catalog.
The fixed oxygen system involves a 48.3 cu. ft. cylinder tied into four overhead "shallow wall" outlets,
and a "push pull" regulator-control mechanism. A 3AA 1800 tank, mounted in the modified tailcone behind
the baggage compartment, is connected to an external fill valve mounted to the fuselage behind fuselage
station bulkhead 191.0. The manifold for the outlets is set up such that the main feed line for the overhead
outlets is connected to the left rear passenger outlet from which the right rear and pilot outlets are connected.
The copilot outlet is connected to the right rear passenger outlet. Push-pull control is provided by a knob on the
overhead panel, to the left of the fresh air duct control. A gauge for displaying tank pressure is mounted in the
overhead duct behind the passengers and is lighted by a post light.
The portable oxygen system uses a 22 cu. ft. capacity, 3AA 1800 cylinder. The tank is incorporated in a
carrying case which utilities a dual manifold, permitting four masks to be used with dual connectors at each
outlet. The portable unit fits in a cradle between the back passenger seats.
Refer to pilot operating handbook for operating instructions.
DO NOT use grease or any type of grease fitting on any
hardware connected to the oxygen system. When working with an
oxygen system make sure hands, clothing, tools, and the
immediate area are free of grease.
Oxygen cylinders are identified by the ICC or DOT identification
stamped on the cylinder. The standard weight cylinder (ICC or
DOT 3AA 1800) must be hydrostatically tested every 5 years. The
month and year of the last test is stamped beneath the ICC, DOT
identification.
PIPER AIRCRAFT
PA-28RT-201 / 201T
MAINTENANCE MANUAL
—WARNING—
—NOTE—
2G23
35-00-01
Page 35-01
Added: November 6, 1979

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Arrow IV Turbo and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Arrow ivPa-28rt-201tPa-28rt-201

Table of Contents

Save PDF