VERITAS 5360 Product Description Manual

VERITAS 5360 Product Description Manual

Hide thumbs Also See for 5360:
Table of Contents

Advertisement

Quick Links

Veritas™ 5360 Appliance
Product Description Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5360 and is the answer not in the manual?

Questions and answers

Summary of Contents for VERITAS 5360

  • Page 1 Veritas™ 5360 Appliance Product Description Guide...
  • Page 2 Technologies LLC or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners. This product may contain third-party software for which Veritas is required to provide attribution to the third party (“Third-party Programs”). Some of the Third-party Programs are available under open source or free software licenses.
  • Page 3 Japan CustomerCare_Japan@veritas.com Documentation Make sure that you have the current version of the documentation. Each document displays the date of the last update on page 2. The latest documentation is available on the Veritas website: https://www.veritas.com/content/support/en_US/dpp.Appliances.html Documentation feedback Your feedback is important to us. Suggest improvements or report errors or omissions to the documentation.
  • Page 4: Table Of Contents

    Locating the appliance serial number ..........9 Compute node drive configurations ..........10 About the drive LEDs .............. 12 About the Veritas 5360 Appliance front panel USB port ......12 About the 5360 Appliance control panel ..........13 About the System Status LED states .......... 15 About the Power button LED states ..........
  • Page 5 Appendix A Technical specifications, Environmental/Protocol standards, and Compliance standards ....65 Veritas 5360 compute node technical specifications ......66 Veritas 5U84 Storage Shelf technical specifications ......68 Environmental specifications ............71 Protocol standards ................ 73 Regulatory, compliance, and certification information ......74 Product regulatory compliance ............
  • Page 6: About The Veritas 5360 Appliance

    ■ Veritas 5360 Appliance overview The Veritas 5360 Appliance is a hardware and software storage system that scales up to a total of 1,920 TiB (2,112 TB) of usable backup capacity. It consists of one or two 2U 5360 Appliance compute nodes and one required externally attached...
  • Page 7: Features And Components Of The Appliance

    Features and components of the appliance Veritas 5360 Appliance Figure 1-1 By itself, the 5360 Appliance compute node does not provide internal disk space for data storage. You can add up to three optional 5U84 Expansion Storage Shelves if you require additional data storage space.
  • Page 8 About the Veritas 5360 Appliance Features and components of the appliance Veritas 5360 Appliance features Table 1-1 Technical Veritas 5360 Appliance system Specification ® ® Processor Intel Xeon Third generation Scalable Processors Appliance software Flex Appliance 3.2 or higher version...
  • Page 9: Locating The Appliance Serial Number

    About the Veritas 5360 Appliance Locating the appliance serial number Veritas 5360 Appliance features (continued) Table 1-1 Technical Veritas 5360 Appliance system Specification RAID levels RAID1 (mirroring) and RAID6 (block level striping with double distributed parity) are used as follows: RAID1: Appliance compute node system disks ■...
  • Page 10: Compute Node Drive Configurations

    The serial number can also be found on the pull-out tab on the front of the appliance. Compute node drive configurations The Veritas 5360 Appliance compute node contains three Opal-compliant SED only 1.92 TB NVMe SSDs. Each SSD is accessible from the compute node's front panel.
  • Page 11 RAID rebuild operation. During the rebuild operation, the appliance dynamically accesses the hot-spare drive and uses it to rebuild the RAID volume. Compute node front drive Figure 1-2 Veritas 5360 Appliance compute node front panel drive Table 1-2 configurations Slot RAID...
  • Page 12: About The Drive Leds

    Power on - the drive is spinning up About the Veritas 5360 Appliance front panel USB port The Veritas 5360 Appliance front panel includes a USB 3.0-compliant port that supports a data transfer rate of up to 500 Mb/second.
  • Page 13: About The 5360 Appliance Control Panel

    About the Veritas 5360 Appliance About the 5360 Appliance control panel About the 5360 Appliance control panel The front control panel provides push button system controls and LED indicators for several system features.
  • Page 14 About the Veritas 5360 Appliance About the 5360 Appliance control panel Control panel system LED descriptions Table 1-5 System information Power button with integrated The Power button toggles the system on and off. This button also functions as a sleep button if enabled by an ACPI compliant operating system.
  • Page 15: About The System Status Led States

    About the Veritas 5360 Appliance About the 5360 Appliance control panel Control panel system LED descriptions (continued) Table 1-5 System information System Cold Reset Button When pressed, this button reboots and re-initializes the system. Unlike the power button, the reset button does not disconnect the power to the system.
  • Page 16 About the Veritas 5360 Appliance About the 5360 Appliance control panel System Status LED states (continued) Table 1-6 Color State Criticality Description Green Solid on (SO) Healthy System is in S5 Soft-Off State ■ Indicates that the system is running (in S0 ■...
  • Page 17 About the Veritas 5360 Appliance About the 5360 Appliance control panel System Status LED states (continued) Table 1-6 Color State Criticality Description Green ~1 Hz blink Degraded System degraded (continued): (continued) BMC Watchdog has reset the BMC. ■ Power unit sensor offset for configuration ■...
  • Page 18: About The Power Button Led States

    About the Veritas 5360 Appliance About the 5360 Appliance control panel System Status LED states (continued) Table 1-6 Color State Criticality Description Amber Solid on Critical, Fatal alarm – system has failed or shutdown: non-recoverable CPU CATERR signal asserted ■...
  • Page 19: About The Compute Node Rear Panel

    The rear panel of the appliance compute node has several access ports and other features. The rear panel of the Veritas 5360 Appliance contains three PCIe riser card assemblies. PCIe riser card assemblies 1 and 2 each support three standard PCIe cards, while PCIe riser card assembly 3 supports two low profile PCIe cards.
  • Page 20 You should not bond copper 1-10 Gb Ethernet ports that are installed in the appliance chassis with PCIe-based 10/25 Gb Ethernet Fibre Channel ports. Veritas appliances may include grounding studs in case your lab environment has such a requirement. The studs are located on the rear panel of the appliance. You can use standard grounding practices to connect grounding wires to the studs.
  • Page 21: Veritas 5360 Appliance I/O Configuration Options

    Figure 1-5 Veritas 5360 Appliance I/O configuration options The rear panel of the Veritas 5360 Appliance contains three PCIe riser card assemblies. PCIe riser card assemblies 1 and 2 each support three standard PCIe cards, while PCIe riser card assembly 3 supports two low profile PCIe cards. The slots are labeled 1 to 8.
  • Page 22 32 Gb 32 Gb GbE NIC FC HBA FC HBA 10/25 10/25 32 Gb 32 Gb 32 Gb FC HBA FC HBA FC HBA For more information, see the Veritas™ Flex 5360 Appliance Cabling Poster. Flex 5360 Model A Figure 1-7...
  • Page 23: Total I/O On-Board And Pcie Ports

    About the Veritas 5360 Appliance Veritas 5360 Appliance I/O configuration options Flex 5360 Model B Figure 1-8 Flex 5360 Model C Figure 1-9 Total I/O on-board and PCIe ports The following table shows the total I/O on-board and PCIe ports options that are...
  • Page 24: Available I/O Configurations By Slot For Veritas 5360 Appliance

    = Fiber optic cable Available I/O configurations by slot for Veritas 5360 Appliance You can use the supported Veritas 5360 Appliance I/O configurations to best serve the needs of your particular environment. The controller is installed in both non-shelf...
  • Page 25: Broadcom P225P 10/25Gb Pcie Ethernet Card

    25GbE SFI transceiver. By default, a 10 GB SFP is shipped with the appliance. Note: Veritas recommends that you use Finisar FTLX8574D3BCV SFP part for 10G connectivity and Broadcom AFBR-735SMZ SFP part for 25G connectivity.
  • Page 26: Qle2772 Dual-Port 32 Gb Fibre Channel Host Bus Adapter

    About the Veritas 5360 Appliance Veritas 5360 Appliance I/O configuration options Broadcom P225p NIC adapter specifications Table 1-12 Item Specification Bracket height Full height Power consumption Typical: 12.5 watts Maximum: 12.9 watts Operating temperature 0°C to 55°C (32 F to 131 F) Storage temperature -40°C to +70°C (-49°F to +221°F)
  • Page 27: Intel Storage Adapter Rs3P4Gf016J

    About the Veritas 5360 Appliance Veritas 5360 Appliance I/O configuration options QLE2772 dual-port 32Gb Fibre Channel host bus adapter Table 1-13 specifications Item Description Bracket Full Height height Form factor Low-profile PCIe card (6.6 inches × 2.731 inches) Power Nominal: 11.0 W consumption Maximum: 13.7 W...
  • Page 28 About the Veritas 5360 Appliance Veritas 5360 Appliance I/O configuration options RS3P4GF016J storage adapter specifications Table 1-14 Item Specification Bracket height Low profile mounting bracket Power consumption Typical: 8.74 watts Maximum: 11.89 watts Operating temperature 0°C to 55°C (32 F to 131 F) Storage temperature -45°C to +105°C (-49°F to +221°F)
  • Page 29: About The Veritas 5U84 Storage Shelves

    About the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf rear ■ components About Veritas 5360 Appliance storage shelves Veritas offers two external storage shelf models for the Veritas 5360 Appliance. These include the: Veritas 5U84 Primary Storage Shelf (required) ■...
  • Page 30 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves Both of the 5U84 Storage Shelf chassis include a set of common internal core components, along with a set of plug-in modules. The core components include: Two sliding disk drawers that contain Disk Drive In Carrier (DDIC) modules ■...
  • Page 31: Available Appliance Storage Options

    Instead, the 5360 Appliance uses the required Veritas 5U84 Primary Storage Shelf as the main data storage device. The 5U84 Primary Storage Shelf connects to the 5360 Appliance compute nodes and uses RAID 6 drive sets to protect the stored data.
  • Page 32 (960TiB) (1920TiB) Veritas 5360 Appliance supports up to 1,056TB (960TiB) of usable MSDP storage capacity. For all storage configurations with an aggregate total of all MSDP pools equaling 960TB or larger, Veritas strongly recommends upgrading the memory capacity to 1536GB.
  • Page 33: About The Veritas 5U84 Storage Shelf Disk Drive Drawers

    5U84 Storage Shelf (capacity with 8TB drives (half and full) Figure 2-2 To determine the hardware configuration for the storage capacities that your environment requires, contact your Veritas sales representative, or your Veritas Partner representative. About the Veritas 5U84 Storage Shelf disk drive drawers This section discusses the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf disk drive drawers and the components that comprise the drawers.
  • Page 34 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves The 5U84 Primary Storage Shelf and the 5U84 Expansion Storage Shelf each use a 5U chassis. Each chassis contains two sliding drawers that are accessible from the front of the storage shelves. Each drawer holds 42 Disk Drive In Carrier (DDIC) modules.
  • Page 35 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves Disk drive slot numbering of a half-populated storage shelf Figure 2-4...
  • Page 36 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves Disk Drive In Carrier (DDIC) modules All storage shelf hard disk drives are housed in DDIC modules. Each disk drive drawer accepts a Disk Drive In Carrier (DDIC) module for each disk drive slot in the drawer.
  • Page 37 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves Disk Drive In Carrier (DDIC) module Figure 2-5...
  • Page 38 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves Disk Drive In Carrier (DDIC) module components and locations Figure 2-6 5U84 Storage Shelf DDIC component locations Table 2-2 Number Component Touch points Note: Touch points are used to facilitate the removal of the DDIC module from the storage shelf drawer.
  • Page 39 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves Disk Drive Drawer printed circuit board (PCB) assemblies Each disk drive drawer in a 5U84 storage shelf uses a printed circuit board (PCB) assembly to provide the electrical connectivity to the drawer's disk drives.
  • Page 40 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves Each PCB assembly contains two Drawer Sideplane cards. One Sideplane card mounts on the right side of the disk drawer, while the other card mounts on the left side of the drawer.
  • Page 41 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves Drawer Baseplane example Figure 2-9 Drawer Sideplane Status panels Drawer Sideplane Status panels are located on the front of the 5U84 storage shelves. These panels provide status and the activity information about the Sideplane card.
  • Page 42 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves 5U84 Primary Storage Shelf / 5U84 Expansion Storage Shelf Figure 2-11 Drawer Sideplane Status panel Drawer Sideplane Status panel descriptions Table 2-4 Number Item Sideplane card OK / Power good...
  • Page 43 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves Drawer Sideplane LED statuses (continued) Table 2-5 Status Power Drawer Fault Cable Fault Logical Fault Activity Bar Graph (Green) (Amber) (Amber) (Amber) (Green) Drive failure has occurred causing...
  • Page 44 About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves Drawer Sideplane hot-swap LED location Figure 2-12 indicators Surrounding metal frame The following table describes the Drawer hot-swap Sideplane LED indicator statuses. Drawer Sideplane Hot-swap LED indicator statuses...
  • Page 45: 5U84 Primary Storage Shelf And The 5U84 Expansion Storage Shelf Control Panel

    About the Veritas 5U84 Storage Shelves About Veritas 5360 Appliance storage shelves 5U84 Primary Storage Shelf and the 5U84 Expansion Storage Shelf control panel The control panel is installed on the left side of both the 5U84 Primary Storage Shelf and the 5U84 Expansion Storage Shelf. It is functionally the same for both systems.
  • Page 46: About The 5U84 Primary Storage Shelf And 5U84 Expansion Storage Shelf Rear Components

    About the Veritas 5U84 Storage Shelves About the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf rear components Control panel functions and descriptions Table 2-7 Number Function Description Unit Identification The Unit Identification Display is a dual digit display that Display provides information about the storage shelf.
  • Page 47 About the Veritas 5U84 Storage Shelves About the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf rear components Fan modules ■ Power Supply Units (PSUs) ■ 5U84 Primary Storage Shelf rear components Figure 2-15 5U84 Primary Storage Shelf rear component locations...
  • Page 48 Shelf disk drives. The RAID controllers also provide RAID data protection technology for the optional 5U84 Expansion Storage Shelves that you connect to the 5U84 Primary Storage Shelf. SAS-3 copper cables connect the 5360 Appliance compute nodes to the 5U84 Primary Storage Shelf through the storage shelf's RAID controllers.
  • Page 49: Veritas 5U84 Primary Storage Shelf Raid Controllers

    52. Veritas 5U84 Primary Storage Shelf RAID controllers The Veritas 5U84 Primary Storage Shelf uses dual, hot swappable SAS-3 RAID controllers. These controllers create and manage the 5U84 Primary Storage Shelf disk drive RAID sets that contain backed up data. They also create and manage the RAID sets on 5U84 Expansion Storage Shelves when those are attached to the 5U84 Primary Storage Shelf.
  • Page 50 Storage Shelf and the first optional 5U84 Expansion Storage Shelf. Veritas 5U84 Primary Storage Shelf SAS-3 RAID controllers Figure 2-17 The following figure and table provides component details for the Veritas 5U84 Primary Storage Shelf SAS-3 RAID controller modules. Veritas 5U84 Primary Storage Shelf SAS-3 RAID Controller...
  • Page 51 Veritas does not use or support the Ethernet port. USB port Serial ports (Service only) Indicator LEDs SAS-3 RAID ports - connects to the 5360 Appliance compute nodes Activity LEDs Expansion SAS port Status Veritas 5U84 Primary Storage Shelf SAS-3 RAID Controller...
  • Page 52: Veritas 5U84 Expansion Storage Shelf Expansion I/O Modules

    Off - Cache is clear or System is coming online Veritas 5U84 Expansion Storage Shelf Expansion I/O modules Veritas 5U84 Expansion Storage Shelf Expansion I/O modules provide SAS-3 data throughput and communications between one or more 5U84 Expansion Storage Shelves.
  • Page 53 Expansion I/O module components and locations Table 2-12 Number Component Expansion I/O module Expansion I/O module Status LEDs RS232 jack (debugging purposes only) SAS-3 ports - A, B, and C Ethernet port Note: Veritas does not use or support the Ethernet port. SAS Activity LEDs...
  • Page 54 About the Veritas 5U84 Storage Shelves About the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf rear components Expansion I/O module Status LED location and conditions This section discusses the location of the Status LEDs on the Expansion I/O modules and the Status LED conditions.
  • Page 55 About the Veritas 5U84 Storage Shelves About the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf rear components Expansion I/O module SAS Activity LED location Figure 2-23 SAS Activity LED location Expansion I/O module SAS Activity LED conditions Table 2-14...
  • Page 56: Veritas 5U84 Storage Shelf Cooling Modules

    About the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf rear components Veritas 5U84 Storage Shelf cooling modules The Veritas 5U84 Storage Shelves include five cooling modules. The cooling modules provide cooling to the entire unit, which is suitable to maintain the internal component temperatures below each components maximum temperature limits.
  • Page 57: 5U84 Storage Shelf Power Supply Units

    PSUs are hot-swappable. You can replace a faulty PSU while the storage shelf is running. However, you must complete the PSU replacement procedure within two minutes after you remove the faulty PSU. Veritas 5U84 Storage Shelf chassis are keyed to prevent PSUs from being inserted upside down. 5U84 Storage Shelf Power Supply Unit...
  • Page 58 About the Veritas 5U84 Storage Shelves About the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf rear components 5U84 Storage Shelf Power Supply Unit Figure 2-26 3 4 5 5U84 Storage Shelf Power Supply Unit component locations Table 2-16...
  • Page 59: Chapter 3 Veritas 5360 Appliance And 5U84 Storage Shelf Cables

    ■ Power cables Each of the AC power modules in both the Veritas 5360 Appliance and the required Veritas 5U84 Primary Storage Shelf accept one AC power cable. The optional 5U84 Expansion Storage Shelf also uses one AC power cord in each of its AC power modules.
  • Page 60 Cable rating: 15A 250V Note: If your power distribution unit is not compatible with the IEC-60320-C14 plug, Veritas recommends that you purchase your power cable locally. Make sure that the power cable meets or exceeds the indicated power rating. “Veritas 5360 compute node technical specifications”...
  • Page 61: Network Cable

    Cable rating: 20A 250V Note: If your power distribution unit is not compatible with the IEC-60320-C20 plug, Veritas recommends that you purchase your power cable locally. Make sure that the power cable meets or exceeds the indicated power rating. “ Veritas 5U84 Storage Shelf technical specifications”...
  • Page 62: Sas-3 Cable

    63. SAS-3 cable SAS-3 data cables are used to connect the Veritas 5U84 Primary Storage Shelf to the 5360 Appliance compute nodes. SAS-3 cables also connect multiple 5U84 Expansion Storage Shelves to each other. SAS-3 cables have SAS-3 connectors on both ends.
  • Page 63: Twinaxial Copper Cables

    63. Twinaxial copper cables The Veritas 5360 Appliance communicates with Ethernet networks through high speed Twinaxial copper cables. If you configure the appliance to communicate with 25 Gb or 10 Gb Ethernet networks, these cables connect to the Ethernet cards in the appliance.
  • Page 64 Veritas 5360 Appliance and 5U84 Storage Shelf cables Twinaxial copper cables “Power cables” on page 59. “Network cable” on page 61. “SAS-3 cable” on page 62.
  • Page 65: Appendix A Technical Specifications, Environmental/Protocol Standards, And Compliance Standards

    Appendix Technical specifications, Environmental/Protocol standards, and Compliance standards This appendix includes the following topics: Veritas 5360 compute node technical specifications ■ Veritas 5U84 Storage Shelf technical specifications ■ Environmental specifications ■ Protocol standards ■ Regulatory, compliance, and certification information ■...
  • Page 66: Veritas 5360 Compute Node Technical Specifications

    Rack information 19" EIA standard The rack rails that are provided for the 5360 Appliance compute node are extensible to 32” (820mm). The minimum distance or depth allowed between the rack posts is 24.6” (623mm). The maximum distance or depth allowed between the rack posts is 37”...
  • Page 67 Note: If your power distribution unit is not compatible with the IEC-60320-C14 plug, Veritas recommends that you purchase your power cable locally. Make sure the power cable meets or exceed the indicated power rating. “Power cables”...
  • Page 68: Veritas 5U84 Storage Shelf Technical Specifications

    70 dBA Veritas 5U84 Storage Shelf technical specifications The following table provides technical specifications for both the Veritas 5U84 Primary Storage Shelf and the Veritas 5U84 Expansion Storage Shelf. Veritas 5U84 Primary Storage Shelf / 5U84 Expansion Storage Table A-2...
  • Page 69 Technical specifications, Environmental/Protocol standards, and Compliance standards Veritas 5U84 Storage Shelf technical specifications Veritas 5U84 Primary Storage Shelf / 5U84 Expansion Storage Table A-2 Shelf technical specifications (continued) Technical specification Description Dimensions (IEC rack 5U84 Primary and 5U84 Expansion Storage Shelves compliant) Height: 22.3 cm (8.75”) (approximately 5U - shelf, overall)
  • Page 70 Expansion I/O module Maximum output power 1400 watts maximum continuous output power at high line voltage You can connect up to four storage shelves to the 5360 Appliance compute nodes. AC power requirements 200 - 240 VAC @ 6.36 A...
  • Page 71: Environmental Specifications

    Technical specifications, Environmental/Protocol standards, and Compliance standards Environmental specifications Veritas 5U84 Primary Storage Shelf / 5U84 Expansion Storage Table A-2 Shelf technical specifications (continued) Technical specification Description Relative humidity Operating: 20%rh to 80%rh non-condensing Non-operating: 5%rh to 100%rh non-condensing Acoustic noise 82 dBA Sound Power Operating ≤...
  • Page 72 The non-operating temperature is defined as the temperature of the system when the system is turned off. It is also referred to as the storage temperature. Veritas recommends that you do not store the system in an environment where the temperatures fall outside of the listed temperature range.
  • Page 73: Protocol Standards

    73. “Regulatory, compliance, and certification information” on page 74. Protocol standards The following table provides standards with which the Veritas 5360 Appliance and the Veritas 5U84 Primary/Expansion Storage Shelf comply. Veritas Appliance / Veritas 5U84 Primary/Expansion Storage Table A-5...
  • Page 74: Regulatory, Compliance, And Certification Information

    Technical specifications, Environmental/Protocol standards, and Compliance standards Regulatory, compliance, and certification information Regulatory, compliance, and certification information The following sections give information about the product regulations and compliance. WARNING To ensure regulatory compliance, you must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals.
  • Page 75: Product Safety Compliance

    Technical specifications, Environmental/Protocol standards, and Compliance standards Product safety compliance Australia / New Zealand ■ KCC South Korea ■ IRAM Certification (Argentina) ■ CCC Certification (China) ■ BIS India ■ NOM Mexico ■ InMetro Brazil ■ NRCS & SABS South Africa ■...
  • Page 76: Product Environmental Compliance

    AS/NZS 3548 Emissions (Australia / New Zealand) ■ Note: For a complete list of regulatory notices please refer to this link: Veritas Safety and Compliance Guide Product environmental compliance Use of banned substances are restricted in accordance with world-wide regulatory requirements.

Table of Contents