Hardware overview
Understanding the NetBackup 5330 hardware installation sequence
Storage shelf and compute node hardware installation sequence
Table 1-3
(continued)
Step
Description
2
Unpack the compute node.
See "Unpacking a NetBackup 5330 compute node" on page 27.
3
Determine the rack locations for the storage shelves and the compute node.
See "Determining rack locations for NetBackup 5330 hardware" on page 29.
4
Mount the storage shelf rails in the rack and install the storage shelves.
Install all Expansion shelves below the Primary Shelf.
The following topic can be used for both the Expansion Shelf and the Primary
Shelf.
See "Installing a Primary Shelf or an Expansion Shelf" on page 34.
5
Install the disk drives into each storage shelf. Be sure to install only 3TB or 6TB
disks into one shelf. You cannot put both types of disks into a single shelf.
See "Installing disk drives into a Primary Shelf or an Expansion Shelf " on page 41.
6
Mount the compute node rails in the rack and install the compute node.
See "Installing the NetBackup 5330 compute node" on page 44.
7
Connect the four fiber channel cables between the Primary Storage Shelf and the
compute node.
See "Connecting a NetBackup 5330 compute node to a Primary Shelf" on page 49.
8
If you are installing one Expansion shelf to a Primary Shelf and a compute node:
Connect four SAS cables between the Expansion Shelf and the Primary Shelf.
See "Connecting one Expansion Shelf to a Primary Shelf" on page 51.
9
If you are adding a second Expansion Shelf to an existing Expansion Shelf, a
Primary Shelf, and a compute node: Connect two new SAS cables between the
two Expansion shelves. Then, disconnect one end of two SAS cables from the
existing Expansion Shelf and connect them to the new Expansion Shelf.
See "Connecting a second Expansion Shelf to an existing 3TB Expansion Shelf
and a 3TB Primary Shelf" on page 55.
10
Connect the Power Distribution Unit (PDU) cords between the compute node and
the power distribution outlets in the rack.
See "Connecting the power cords to the hardware" on page 66.