Information List; A.9 Information List - Siemens SIPROTEC 7SJ62 Manual

Multi-functional protective relay with local control
Hide thumbs Also See for SIPROTEC 7SJ62:
Table of Contents

Advertisement

A.9

Information List

Indications for IEC 60 870-5-103 are always reported ON / OFF if they are subject to general interrogation for
IEC 60 870-5-103. If not, they are reported only as ON.
New user-defined indications or such newly allocated to IEC 60 870-5-103 are set to ON / OFF and subjected
to general interrogation if the information type is not a spontaneous event („.._Ev"). Further information with
regard to the indications is set out in the SIPROTEC 4 System Description, Order No. E50417-H1100-C151.
In columns „Event Log", „Trip Log" and „Ground Fault Log" the following applies:
UPPER CASE NOTATION "ON/OFF": definitely set, not allocatable
lower case notation "on/off":
*:
<blank>:
In column „Marked in Oscill.Record" the following applies:
UPPER CASE NOTATION "M":
lower case notation "m":
*:
<blank>:
No.
Description
-
>Back Light on (>Light on)
-
Reset LED (Reset LED)
-
Stop data transmission (DataS-
top)
-
Test mode (Test mode)
-
Feeder GROUNDED (Feeder
gnd)
-
Breaker OPENED (Brk
OPENED)
-
Hardware Test Mode (HWTest-
Mod)
-
Clock Synchronization (Synch-
Clock)
-
Error FMS FO 1 (Error FMS1)
-
Error FMS FO 2 (Error FMS2)
-
Disturbance CFC (Distur.CFC)
-
Fault Recording Start (FltRecSta) Osc. Fault Rec.
-
Setting Group A is active
(GroupA act)
-
Setting Group B is active
(GroupB act)
SIPROTEC, 7SJ62/64, Manual
C53000-G1140-C207-2, Release date 01.2008
preset, allocatable
not preset, allocatable
neither preset nor allocatable
definitely set, not allocatable
preset, allocatable
not preset, allocatable
neither preset nor allocatable
Function
Type
of In-
for-
matio
n
Device, General
SP
On
Off
Device, General
IntSP
on
Device, General
IntSP
On
Off
Device, General
IntSP
On
Off
Device, General
IntSP
*
Device, General
IntSP
*
Device, General
IntSP
On
Off
Device, General
IntSP
*
_Ev
Device, General
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
Off
IntSP
On
Off
Change Group
IntSP
On
Off
Change Group
IntSP
On
Off
Log Buffers
Configurable in Matrix
*
*
LED BI
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
*
LED
*
LED
*
LED
*
m
LED
*
*
LED
*
*
LED
Appendix

A.9 Information List

IEC 60870-5-103
BO
BO
160
19
1
No
BO
160
20
1
Yes
BO
160
21
1
Yes
BO
BO
BO
BO
BO
BO
BO
BO
160
23
1
Yes
BO
160
24
1
Yes
653

Advertisement

Table of Contents
loading

Table of Contents