A.8 Settings
Addr.
Parameter
2107
67Nc-TOC T-DIAL
2201
INRUSH REST.
2202
2nd HARMONIC
2203
CROSS BLOCK
2204
CROSS BLK TIMER
2205
I Max
2701
50 1Ph
2702
50 1Ph-2 PICKUP
2703
50 1Ph-2 PICKUP
2704
50 1Ph-2 DELAY
2705
50 1Ph-1 PICKUP
2706
50 1Ph-1 PICKUP
2707
50 1Ph-1 DELAY
3101
Sens. Gnd Fault
3102
CT Err. I1
3102
CT Err. I1
3103
CT Err. F1
3104
CT Err. I2
3104
CT Err. I2
3105
CT Err. F2
3106
VPH MIN
3107
VPH MAX
3108
64-1 VGND
3109
64-1 VGND
3110
64-1 VGND
3111
T-DELAY Pickup
3112
64-1 DELAY
3113
50Ns-2 PICKUP
3113
50Ns-2 PICKUP
3114
50Ns-2 DELAY
3115
67Ns-2 DIRECT
3117
50Ns-1 PICKUP
3117
50Ns-1 PICKUP
3118
50Ns-1 DELAY
3119
51Ns PICKUP
3119
51Ns PICKUP
3119
51Ns PICKUP
636
Function
C
Setting Options
0.50 .. 15.00 ; ∞
ColdLoadPickup
50/51 Overcur.
OFF
ON
50/51 Overcur.
10 .. 45 %
50/51 Overcur.
NO
YES
50/51 Overcur.
0.00 .. 180.00 sec
50/51 Overcur.
1A
0.30 .. 25.00 A
5A
1.50 .. 125.00 A
50 1Ph
OFF
ON
0.05 .. 35.00 A; ∞
50 1Ph
1A
0.25 .. 175.00 A; ∞
5A
0.003 .. 1.500 A; ∞
50 1Ph
0.00 .. 60.00 sec; ∞
50 1Ph
0.05 .. 35.00 A; ∞
50 1Ph
1A
0.25 .. 175.00 A; ∞
5A
0.003 .. 1.500 A; ∞
50 1Ph
0.00 .. 60.00 sec; ∞
50 1Ph
Sens. Gnd Fault
OFF
ON
ON with GF log
Alarm Only
Sens. Gnd Fault
0.001 .. 1.600 A
Sens. Gnd Fault
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
Sens. Gnd Fault
0.0 .. 5.0 °
Sens. Gnd Fault
0.001 .. 1.600 A
Sens. Gnd Fault
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
Sens. Gnd Fault
0.0 .. 5.0 °
Sens. Gnd Fault
10 .. 100 V
Sens. Gnd Fault
10 .. 100 V
1.8 .. 200.0 V; ∞
Sens. Gnd Fault
1.8 .. 170.0 V; ∞
Sens. Gnd Fault
10.0 .. 225.0 V; ∞
Sens. Gnd Fault
0.04 .. 320.00 sec; ∞
Sens. Gnd Fault
0.10 .. 40000.00 sec; ∞
Sens. Gnd Fault
Sens. Gnd Fault
0.001 .. 1.500 A
Sens. Gnd Fault
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
0.00 .. 320.00 sec; ∞
Sens. Gnd Fault
Sens. Gnd Fault
Forward
Reverse
Non-Directional
Sens. Gnd Fault
0.001 .. 1.500 A
Sens. Gnd Fault
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
0.00 .. 320.00 sec; ∞
Sens. Gnd Fault
Sens. Gnd Fault
0.001 .. 1.400 A
Sens. Gnd Fault
0.003 .. 0.500 A
Sens. Gnd Fault
1A
0.05 .. 4.00 A
5A
0.25 .. 20.00 A
Default Setting
5.00
67Nc-TOC Time Dial
OFF
Inrush Restraint
15 %
2nd. harmonic in % of fundamen-
tal
NO
Cross Block
0.00 sec
Cross Block Time
7.50 A
Maximum Current for Inrush Re-
straint
37.50 A
OFF
50 1Ph
0.50 A
50 1Ph-2 Pickup
2.50 A
0.300 A
50 1Ph-2 Pickup
0.10 sec
50 1Ph-2 Time Delay
0.20 A
50 1Ph-1 Pickup
1.00 A
0.100 A
50 1Ph-1 Pickup
0.50 sec
50 1Ph-1 Time Delay
OFF
(Sensitive) Ground Fault
0.050 A
Current I1 for CT Angle Error
1.00 A
Current I1 for CT Angle Error
5.00 A
0.0 °
CT Angle Error at I1
1.000 A
Current I2 for CT Angle Error
10.00 A
Current I2 for CT Angle Error
50.00 A
0.0 °
CT Angle Error at I2
40 V
L-Gnd Voltage of Faulted Phase
Vph Min
75 V
L-Gnd Voltage of Unfaulted
Phase Vph Max
40.0 V
64-1 Ground Displacement
Voltage
40.0 V
64-1 Ground Displacement
Voltage
70.0 V
64-1 Ground Displacement
Voltage
1.00 sec
Time-DELAY Pickup
10.00 sec
64-1 Time Delay
0.300 A
50Ns-2 Pickup
10.00 A
50Ns-2 Pickup
50.00 A
1.00 sec
50Ns-2 Time Delay
Forward
67Ns-2 Direction
0.100 A
50Ns-1 Pickup
2.00 A
50Ns-1 Pickup
10.00 A
2.00 sec
50Ns-1 Time delay
0.100 A
51Ns Pickup
0.004 A
51Ns Pickup
1.00 A
51Ns Pickup
5.00 A
SIPROTEC, 7SJ62/64, Manual
C53000-G1140-C207-2, Release date 01.2008
Comments