556
Functions
V, f, P 67/67N
Directional overcurrent protection
27/59
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
81O/U
Under/Overfrequency
27/47/59(N)/
Flexible protection functions (parameters from current
32/55/81R
and voltage): Voltage, power, power factor, frequency
change protection
67/67N
Directional overcurrent protection
Intermittent ground fault
67/67N
Directional overcurrent protection
67Ns
Directional sensitive ground fault detection
87N
High-impedance ground fault differential protection
U, f, P 67Ns
Sensitive ground fault detection
87N
High-impedance ground fault protection
27/59
High-impedance ground fault protection
81U/O
Under/Overfrequency
27/47/59(N)/
Flexible protection functions (parameters from current
32/55/81R
and voltage): Voltage, power, power factor, frequency
change protection
67/67N
Directional overcurrent protection
67Ns
Directional sensitive ground fault detection
87N
High-impedance ground fault differential protection
Intermittent ground fault
67Ns
Directional sensitive ground fault detection
87N
High-impedance ground fault differential protection
V, f, P 67Ns
Directional sensitive ground fault detection
87N
High-impedance ground fault differential protection
48/14
Motor starting protection, locked rotor
66/86
Restart inhibit for motors
51M
Load jam protection in motors, motor statistics
27/59
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
81O/U
Under/Overfrequency
27/47/59(N)/
Flexible protection functions (parameters from current
32/55/81R
and voltage): Voltage, power, power factor, frequency
change protection
V, f, P 67/67N
Directional overcurrent protection
67Ns
Directional sensitive ground fault detection
87N
High-impedance ground fault differential protection
48/14
Motor starting protection, locked rotor
66/86
Restart inhibit for motors
51M
Load jam protection in motors, motor statistics
27/59
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
81O/U
Under/Overfrequency
27/47/59(N)/
Flexible protection functions (parameters from current
32/55/81R
and voltage): Voltage, power, power factor, frequency
change protection
SIPROTEC, 7SJ62/64, Manual
C53000-G1140-C207-2, Release date 01.2008
Pos. 14
and 15
F G
P C
1)
F D
1)
F F
1)
P D
1)
F B
1)
H F
1)
H H

Advertisement

Table of Contents
loading

Table of Contents