Siemens SIPROTEC 7SJ62 Manual page 639

Multi-functional protective relay with local control
Hide thumbs Also See for SIPROTEC 7SJ62:
Table of Contents

Advertisement

Addr.
Parameter
4311
ROTOR OVERLOAD
4401
Load Jam Prot.
4402
Load Jam I>
4403
TRIP DELAY
4404
I Alarm
4405
ALARM DELAY
4406
T Start Blk.
5001
FCT 59
5002
59-1 PICKUP
5003
59-1 PICKUP
5004
59-1 DELAY
5005
59-2 PICKUP
5006
59-2 PICKUP
5007
59-2 DELAY
5015
59-1-V2 PICKUP
5016
59-2-V2 PICKUP
5017A
59-1 DOUT RATIO
5018A
59-2 DOUT RATIO
5019
59-1 PICKUP V1
5020
59-2 PICKUP V1
5101
FCT 27
5102
27-1 PICKUP
5103
27-1 PICKUP
5106
27-1 DELAY
5110
27-2 PICKUP
5111
27-2 PICKUP
5112
27-2 DELAY
5113A
27-1 DOUT RATIO
5114A
27-2 DOUT RATIO
5120A
CURRENT SUPERV.
5201
VT BROKEN WIRE
Σ V>
5202
5203
Vph-ph max<
5204
Vph-ph min<
5205
Vph-ph max-min>
5206
I min>
5208
T DELAY ALARM
5301
FUSE FAIL MON.
5302
FUSE FAIL 3Vo
SIPROTEC, 7SJ62/64, Manual
C53000-G1140-C207-2, Release date 01.2008
Function
C
Setting Options
48/66 Motorprot
ON
OFF
Alarm Only
48/66 Motorprot
OFF
ON
Alarm Only
48/66 Motorprot
1A
0.50 .. 12.00 A
5A
2.50 .. 60.00 A
48/66 Motorprot
0.00 .. 600.00 sec
48/66 Motorprot
1A
0.50 .. 12.00 A
5A
2.50 .. 60.00 A
48/66 Motorprot
0.00 .. 600.00 sec
48/66 Motorprot
0.00 .. 600.00 sec
27/59 O/U Volt.
OFF
ON
Alarm Only
27/59 O/U Volt.
40 .. 260 V
27/59 O/U Volt.
40 .. 150 V
0.00 .. 100.00 sec; ∞
27/59 O/U Volt.
27/59 O/U Volt.
40 .. 260 V
27/59 O/U Volt.
40 .. 150 V
0.00 .. 100.00 sec; ∞
27/59 O/U Volt.
27/59 O/U Volt.
2 .. 150 V
27/59 O/U Volt.
2 .. 150 V
27/59 O/U Volt.
0.90 .. 0.99
27/59 O/U Volt.
0.90 .. 0.99
27/59 O/U Volt.
40 .. 150 V
27/59 O/U Volt.
40 .. 150 V
27/59 O/U Volt.
OFF
ON
Alarm Only
27/59 O/U Volt.
10 .. 210 V
27/59 O/U Volt.
10 .. 120 V
0.00 .. 100.00 sec; ∞
27/59 O/U Volt.
27/59 O/U Volt.
10 .. 210 V
27/59 O/U Volt.
10 .. 120 V
0.00 .. 100.00 sec; ∞
27/59 O/U Volt.
27/59 O/U Volt.
1.01 .. 3.00
27/59 O/U Volt.
1.01 .. 3.00
27/59 O/U Volt.
OFF
ON
Measurem.Superv
ON
OFF
Measurem.Superv
1.0 .. 100.0 V
Measurem.Superv
1.0 .. 100.0 V
Measurem.Superv
1.0 .. 100.0 V
Measurem.Superv
10.0 .. 200.0 V
Measurem.Superv
1A
0.04 .. 1.00 A
5A
0.20 .. 5.00 A
Measurem.Superv
0.00 .. 32.00 sec
Measurem.Superv
OFF
Solid grounded
Coil.gnd./isol.
Measurem.Superv
10 .. 100 V
Default Setting
ON
Rotor Overload Protection
OFF
Load Jam Protection
2.00 A
Load Jam Tripping Threshold
10.00 A
1.00 sec
Load Jam Trip Delay
1.80 A
Load Jam Alarm Threshold
9.00 A
1.00 sec
Load Jam Alarm Delay
10.00 sec
Load Jam Blocking after motor
start
OFF
59 Overvoltage Protection
110 V
59-1 Pickup
110 V
59-1 Pickup
0.50 sec
59-1 Time Delay
120 V
59-2 Pickup
120 V
59-2 Pickup
0.50 sec
59-2 Time Delay
30 V
59-1 Pickup Overvoltage (neg.
seq.)
50 V
59-2 Pickup Overvoltage (neg.
seq.)
0.95
59-1 Dropout Ratio
0.95
59-2 Dropout Ratio
110 V
59-1 Pickup V1
120 V
59-2 Pickup V1
OFF
27 Undervoltage Protection
75 V
27-1 Pickup
75 V
27-1 Pickup
1.50 sec
27-1 Time Delay
70 V
27-2 Pickup
70 V
27-2 Pickup
0.50 sec
27-2 Time Delay
1.20
27-1 Dropout Ratio
1.20
27-2 Dropout Ratio
ON
Current Supervision
OFF
VT broken wire supervision
8.0 V
Threshold voltage sum
16.0 V
Maximum phase to phase
voltage
16.0 V
Minimum phase to phase voltage
16.0 V
Symmetry phase to phase volt-
ages
0.04 A
Minimum line current
0.20 A
1.25 sec
Alarm delay time
OFF
Fuse Fail Monitor
30 V
Zero Sequence Voltage
Appendix
A.8 Settings
Comments
639

Advertisement

Table of Contents
loading