Setting (p29340/p29341)
If warning condition assigned to p29340 occurs, WARNING1 becomes ON.
If warning condition assigned to p29341 occurs, WARNING2 becomes ON.
Wiring
The digital outputs only support NPN type of wiring as illustrated below:
4.3.2
Pulse train inputs/encoder outputs (PTIs/PTOs)
4.3.2.1
PTIs
Two channels of pulse train input are available for the SINAMICS V90 servo drive:
● 24 V single end pulse train input
● High-speed 5 V differential pulse train input (RS485)
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
5
Motor overheat: motor has reached 85% of the maximum allowed
motor temperature.
6
Lifetime detection: the life expectancy of the capacity or the fan is
shorter than the specified time.
4.3 Control/status interface - X8
Warning conditions
Connecting
97