10.2 Parameter list
Par. No.
Name
p29142
PI to P switching condi-
tion: Speed
Description: Triggers speed threshold for PI/P switching. If the PI/P switching function is enabled and this
condition is selected:
Switch from the PI control to the P control when the actual speed is larger than the threshold.
Switch from the P control to the PI control when the actual speed is smaller than the threshold.
p29143
PI to P switching condi-
tion: Acceleration
Description: Triggers acceleration threshold for PI/P switching. If the PI/P switching function is enabled and
this condition is selected:
Switch from the PI control to the P control when the actual acceleration is larger than the threshold.
Switch from the P control to the PI control when the actual acceleration is smaller than the threshold.
p29144
PI to P switching condi-
tion: Pulse deviation
Description: Triggers pulse deviation threshold for PI/P switching. If the PI/P switching function is enabled and
this condition is selected:
Switch from the PI control to the P control when the actual pulse deviation is larger than the threshold.
Switch from the P control to the PI control when the actual pulse deviation is smaller than the threshold.
p29230
MDI direction selection
Description: MDI direction selection:
0: Absolute positioning through the shortest distance
1: Absolute positioning through the positive direction
2: Absolute positioning through the negative direction
p29240
Select referencing mode
Description: Selects referencing mode.
0: Referencing with external signal REF
1: Referencing with external reference cam (signal REF)
2: Referencing with zero mark only
3: Referencing with external reference cam (CCWL) and zero mark
4: Referencing with external reference cam (CWL) and zero mark
p29241
Positioning mode selec-
tion
Description: Moves mode set for IPos:
0: Means relative moving
1: Means abs moving
2: POS Mod
3: NEG Mod
310
Min
Max
0
210000
0
30000
0
214748364
7
0
2
0
4
0
3
Factory
Unit
Data
Setting
type
2000
rpm
Float
20
rev/
Float
30000
LU
U32
0
-
I16
1
-
I16
0
-
U16
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Effective
Can be
changed
IM
T
IM
T
IM
T
IM
T
IM
T
IM
T