Fault
F7475: EPOS: Target posi-
tion < start of traversing
range
Reaction: OFF1 (OFF2,
OFF3)
Acknowledgement:
IMMEDIATELY
F7476: EPOS: Target posi-
tion > end of the traversing
range
Reaction: OFF1 (OFF2,
OFF3)
Acknowledgement:
IMMEDIATELY
F7481: EPOS: Axis position <
software limit switch minus
Reaction: OFF1 (OFF2,
OFF3)
Acknowledgement:
IMMEDIATELY
F7482: EPOS: Axis position >
software limit switch plus
Reaction: OFF1 (OFF2,
OFF3)
Acknowledgement:
IMMEDIATELY
F7484: Fixed stop outside the
monitoring window
Reaction: OFF1 (OFF2,
OFF3)
Acknowledgement:
IMMEDIATELY
F7485: Fixed stop not
reached
Reaction: OFF1 (OFF2,
OFF3)
Acknowledgement:
IMMEDIATELY
F7488: EPOS: Relative posi-
tioning not possible
Reaction: OFF1 (OFF2,
OFF3)
Acknowledgement:
IMMEDIATELY
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Cause
The target position for relative traversing
lies outside the traversing range.
The target position for relative traversing
lies outside the traversing range.
The actual position of the axis is less than
the position of the software limit switch
minus.
The actual position of the axis is greater
than the position of the software limit
switch plus.
In the "fixed stop reached" state, the axis
has moved outside the defined monitoring
window (p2635).
In a traversing block with the task FIXED
STOP, the end position was reached with-
out detecting a fixed stop.
In the mode "direct setpoint input/MDI", for
continuous transfer relative positioning
was selected.
11.2 List of faults and alarms
Remedy
Correct the target position.
Correct the target position.
Correct the target position.
Change software limit switch minus (CI:
p2580).
Correct the target position.
Change software limit switch plus (CI:
p2581).
Check the monitoring window (p2635).
Check the mechanical system.
Check the traversing block and locate the
target position further into the workpiece.
Check the "fixed stop reached" control
signal.
If required, reduce the maximum following
error window to detect the fixed stop
(p2634).
Check the control.
Diagnostics
335