Par. No.
Name
p29132
Gain switching condition:
Position setpoint frequen-
cy
Description: Triggers pulse input frequency (PTI) threshold or internal position speed (IPos) threshold for gain
switching. If the gain switching function is enabled and this condition is selected:
1. PTI
Switch from the first group of control parameters to the second group when the pulse train input pulse
is higher than the threshold.
Switch from the second group of control parameters to the first group when the pulse train input is low-
er than the threshold.
2. IPos
Switch from the first group of control parameters to the second group when the speed of fixed position
setpoint is larger than the threshold.
Switch from the second group of control parameters to the first group when the IPos is smaller than the
threshold.
p29133
Gain switching condition:
Actual speed
Description: Triggers speed threshold for gain switching. If the gain switching function is enabled and this
condition is selected:
Switch from the first group of control parameters to the second group when the actual motor speed is
larger than the threshold.
Switch from the second group of control parameters to the first group when the actual motor speed is
smaller than the threshold.
p29139
Gain switching time con-
stant
Description: Time constant for gain switching. Set this parameter to avoid frequent gain switches that reduces
system reliability.
p29140
PI to P: Mode selection
Description: Selects a condition for the switch from PI control to P control under the speed loop.
0: Disabled
1: Torque is higher than a parameterizable setting value.
2: Using the digital input signal (G-CHANGE).
3: Speed is higher than a parameterizable setting value.
4: Acceleration is higher than a parameterizable setting value.
5: Pulse deviation is higher than a parameterizable setting value.
Note: Only when the auto tuning function (p29021=0) and gain switching function are both disabled can the
PI/P switching function be used.
p29141
PI to P switching condi-
tion: Torque
Description: Triggers torque threshold for PI/P switching. If the PI/P switching function is enabled and this
condition is selected:
Switch from the PI control to the P control when the actual torque is larger than the threshold.
Switch from the P control to the PI control when the actual torque is smaller than the threshold.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Min
Max
0
214700006
4
0
214700006
4
8
1000
0
5
0
300
Factory
Unit
Data
Setting
type
100
100
Float
0
LU/
min
100
rpm
Float
20
ms
Float
0
-
U16
200
%
Float
Parameters
10.2 Parameter list
Effective
Can be
changed
IM
T
IM
T
IM
T
IM
T
IM
T
309