Siemens SINAMICS V90 Operating Instructions Manual page 294

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Parameters
10.2 Parameter list
Par. No.
Name
p1670
Current setpoint filter 3
numerator natural fre-
quency
Description: Sets the numerator natural frequency for current setpoint filter 3 (general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1671
Current setpoint filter 3
numerator damping
Description: Sets the numerator damping for current setpoint filter 3.
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1673
Current setpoint filter 4
denominator natural fre-
quency
Description: Sets the denominator natural frequency for current setpoint filter 4 (PT2, general filter).
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1674
Current setpoint filter 4
denominator damping
Description: Sets the denominator damping for current setpoint filter 4.
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1675
Current setpoint filter 4
numerator natural fre-
quency
Description: Sets the numerator natural frequency for current setpoint filter 4 (general filter).
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1676
Current setpoint filter 4
numerator damping
Description: Sets the numerator damping for current setpoint filter 4.
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p2153
Speed actual value filter
time constant
Description: Sets the time constant of the PT1 element to smooth the speed/velocity actual value.
The smoothed actual speed/velocity is compared with the threshold values and is only used for messages and
signals.
p2161 *
Speed threshold 3
Description: Sets the speed threshold value for the signal that indicates the axis is stationary.
p2162 *
Hysteresis speed n_act >
n_max
Description: Sets the hysteresis speed (bandwidth) for the signal "n_act > n_max".
294
Min
Max
0.5
16000.0
0.000
10.000
0.5
16000.0
0.001
10.000
0.5
16000.0
0.000
10.000
0
1000000
0.00
210000.00
0.00
60000.00
Factory
Unit
Data
Setting
type
1000.0
Hz
Float
0.010
-
Float
1000.0
Hz
Float
0.300
-
Float
1000.0
Hz
Float
0.010
-
Float
0
ms
Float
10.00
rpm
Float
0.00
rpm
Float
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6

Table of Contents