Overview of important parameters
• p2621[0...7]
• p2634
• p2635
For more information about the parameters above, see Section "Parameter list (Page 286)".
7.2.2

Servo ON

Servo ON signal (SON)
Signal
Signal name
type
DI
SON
Relevant parameter settings
Parameter
Value setting
p29301
1
p29300
bit 0 = 1
Note
Refer to Section "Digital inputs/outputs (DIs/DOs) (Page 89)" for detailed information about
DI parameterization.
Refer to Chapter "Parameters (Page 285)" for detailed information about parameters.
Note
When you set bit 0 of p29300 to 1, the following apply:
• After the drive is powered on, it will be set to "S ON" state automatically.
• After a fault is acknowledged, the drive will be set to "S ON" state automatically.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Internal position task
Fixed stop maximum following error
Fixed stop monitoring window
Pin assignment
Setting
X8-5 (factory
ON = rising
setting)
edge
OFF = falling
edge
Signal SON (signal number: 1) is assigned to digital input 1 (DI1).
Set signal SON at a high level forcedly.
Description
Servo motor circuit is connected (the motor is in
"S ON" state). Servo motor is ready to run.
Servo motor circuit is shut off (the motor is in "S OFF"
state). Servo motor is not ready to run.