Par. No.
Name
Note: The percentage value refers to the maximum deceleration (p2573).
p29000 *
Motor ID
Description: Motor type number is printed on the motor rating plate as motor ID.
For a motor with an incremental encoder, users need to manually input the parameter value. The range of
high inertia motor is 18 to 39; the range of low inertia motor is 42 to 71.
For a motor with an absolute encoder, the drive automatically reads the parameter value. The range of high
inertia motor with multi-turn encoder is 10009 to 10048.
p29001
Reversal of motor direc-
tion
Description: Reversal of motor running direction. By default, CW is the positive direction while CCW the nega-
tive direction. After changing of p29001, reference point will lost, A7461 will remind user to referencing again.
0: No reversal
1: Reverse
p29002
BOP display selection
Description: Selection of BOP operating display.
0: Actual speed (default)
1: DC voltage
2: Actual torque
3: Actual position
4: Position following error
p29003
Control mode
Description: Selection of control mode.
0: Position control with pulse train input (PTI)
1: Internal position control (IPos)
2: Speed control (S)
3: Torque control (T)
4: Control change mode: PTI/S
5: Control change mode: IPos/S
6: Control change mode: PTI/T
7: Control change mode: IPos/T
8: Control change mode: S/T
Note: The compound control mode can be controlled by the digital input signal C-MODE. When DI10 (C-
MODE) is 0, the first control mode of control change mode is selected; otherwise, the second one is selected.
p29004
RS485 address
Description: Configuration of the RS485 bus address. The RS485 bus is used to transfer current absolute
position of the servo drive to the controller/PLC.
Note: Changes only become effective after power on. The parameter isn't influenced by default function.
p29005
Braking resistor capacity
percentage alarm thresh-
old
Description: Alarm triggering threshold for the capacity of the internal braking resistor.
Alarm number: A52901
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Min
Max
0
65535
0
1
0
4
0
8
1
31
1
100
Factory
Unit
Data
Setting
type
0
-
U16
0
-
I16
0
-
I16
0
-
I16
1
-
U16
100
%
Float
Parameters
10.2 Parameter list
Effective
Can be
changed
IM
T
IM
T
IM
T, U
RE
T
RE
T
IM
T
301