Process Parameters For Synchropulse - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

Process parame-
The following process parameters can be set for SynchroPulse welding:
ters for Synchro-
Pulse
(1) Synchropulse
to activate/deactivate SynchroPulse
Unit
Setting range
Factory setting
(2) Wire feed speed
for setting the wire speed and therefore the welding power for SynchroPulse
Unit
Setting range
Factory setting
(3) Delta wire feed
For setting the Delta wire feed:
in SynchroPulse, the set wire speed is alternately increased/reduced by the Delta wire
feed. The parameters concerned adapt themselves to this wire speed acceleration/delay
accordingly.
Unit
Setting range
Factory setting
(4) Frequency F
for setting the frequency for SynchroPulse
Unit
Setting range
Factory setting
(5) Duty Cycle (high)
for weighting the duration of the higher operating point in a SynchroPulse period
Unit
Setting range
Factory setting
(6) Arc-length correction high
for correcting the arc length for SynchroPulse in the upper operating point (= average wire
speed plus Delta wire feed)
Unit
Setting range
Factory setting
-
0
+
110
-
off / on
off
m/min (ipm)
1.0 - 25.0 (40 - 985)
5.0
m/min (ipm)
0.1 - 6.0 (5 - 235)
2.0
Hz
0.5 - 3.0
3.0
%
10 - 90
50
-
-10.0 - +10.0
0.0
short arc
uncorrected arc length
longer arc