TPS 400i LSC
Mains voltage (U
ADV
Max. effective primary current (I
Max. primary current (I
Mains fuse protection
Mains voltage tolerance
Mains frequency
Cos phi (1)
Max. permitted mains impedance Z
Recommended earth-leakage circuit breaker
Welding current range (I
MIG/MAG
TIG
Rod electrode
Welding current at
Output voltage range according to standard characteristic (U
MIG/MAG
TIG
Rod electrode
Open circuit voltage (U
Degree of protection
Type of cooling
Overvoltage category
Pollution level according to IEC60664
EMC device class
Safety symbols
Dimensions (l x w x h)
Weight
Max. noise emission (LWA)
1)
2)
176
)
1
)
1max
)
2
10 min/40 °C (104 °F)
peak / U
0
Interface to a 230/400 V, 50 Hz public grid
A Class A equipment is not intended for use in residential locations where the elec-
trical power is provided by the public low-voltage supply system.
There can be potential difficulties in ensuring electromagnetic compatibility in those
locations, due to conducted as well as radiated radio-frequency disturbances.
)
1eff
1)
on PCC
max
r.m.s)
0
3 x
400 V
16.4 A
25.1 A
35 A slow-blow
+/-15%
50/60 Hz
0.99
92 mOhm
Type B
3 - 400 A
3 - 400 A
10 - 400 A
40%
60%
100%
400 A
360 A
320 A
)
2
14.2 - 34.0 V
10.1 - 26.0 V
20.4 - 36.0 V
73 V
IP 23
S, CE
706 x 300 x 720 mm
27.8 x 11.8 x 28.3 in.
55.7 kg
122.8 lb.
77 dB (A)
AF
III
3
2)
A