Tps 320I /600V/Nc - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

TPS 320i /600V/nc

Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Mains fuse protection
Mains voltage tolerance
Mains frequency
Cos phi (1)
Recommended earth-leakage circuit breaker
Welding current range (I
MIG/MAG
TIG
Rod electrode
Welding current at
Output voltage range according to standard characteristic (U
MIG/MAG
TIG
Rod electrode
Open circuit voltage (U
Degree of protection
Type of cooling
Overvoltage category
Pollution level according to IEC60664
Safety symbols
Dimensions (l x w x h)
Weight
Max. noise emission (LWA)
170
)
1
)
1eff
)
1max
)
2
10 min/40 °C (104 °F)
peak / U
r.m.s)
0
0
3 x
575 V
10.6 A
16.7 A
35 A slow-blow
+/-10%
50/60 Hz
0.99
Type B
3 - 320 A
3 - 320 A
10 - 320 A
40%
60%
100%
320 A
260 A
240 A
)
2
14.2 - 30.0 V
10.1 - 22.8 V
20.4 - 32.8 V
67 V
IP 23
S, CSA
706 x 300 x 510 mm
27.8 x 11.8 x 20.1 in.
32.7 kg
72.1 lb.
74 dB (A)
AF
III
3