NOTE!
All parameter set values that are set using the dial are saved until their next al-
teration.
This applies even if the welding system is switched off and on again.
10
Welding para-
meters
I
S
t
up
I
1
Adjust quantity of shielding gas:
Press the gas-test button
The gas pre-flow test lasts for 30 seconds at the most. Press the button
again to stop the gas flow prematurely.
Turn the adjusting screw on the bottom of the gas pressure regulator until
the manometer displays the desired quantity of gas
Commence the welding process (ignite arc)
Starting current
1 - 200% of the main current I
Factory setting 35%
UpSlope
off / 0.01 - 9.9 s
Factory setting: 0.5 s
IMPORTANT! The UpSlope t
ating modes:
-
2-step mode
-
4-step mode
-
When the "Trigger" setup parameter is set to "oFF"
-
When a foot-operated remote control has been connected
Main current
10 – 170 A ... Artis 170
10 – 210 A ... Artis 210
Factory setting: 100 A
1
is saved separately for the following oper-
up
51