Process Parameters For Synchropulse - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

Process parame-
The following process parameters can be set for SynchroPulse welding:
ters for Synchro-
Pulse
Synchropulse
to activate/deactivate SynchroPulse
Unit
Setting range
Factory setting
(1) Wire feed speed
for setting the wire feed speed and therefore the welding power for SynchroPulse
Unit
Setting range
Factory setting
(2) WFS deviation
for setting the wire feed speed deviation:
in SynchroPulse, the set wire feed speed is alternately increased/reduced by the wire
feed speed deviation. The parameters concerned adapt themselves to this wire feed
speed acceleration/delay accordingly.
Unit
Setting range
Factory setting
(3) Frequency F
Unit
Setting range
Factory setting
112
for setting the frequency for SynchroPulse
-
off / on
off
m/min (ipm)
1.0 - 25.0 (40 - 985)
5
m/min (ipm)
0.1 - 6.0 (5 - 235)
2.0
Hz
0.5 - 3.0
3