Process parameters, Job

Optimising job
The following process parameters can be set for the job:
process parame-
ters
Job parameters
Wire speed
To adjust the wire speed
Unit
Setting range
Arc length correction
For correcting the arc length
Unit
Setting range
-
0
+
Pulse/Arc-force dynamic correction
To correct the pulse energy for pulsed arc welding
Setting range
-
0
+
To influence the short-circuiting dynamic at the moment of droplet transfer in standard arc
welding
-
0
+
The other adjustable process parameters correspond to the process parameters already
described:
Start/end of welding
-
-
-
-
-
-
-
-
-
-
m/min (ipm)
1.0–25.0 (40–985)
-
-10.0 – +10.0
short arc
uncorrected arc length
longer arc
-10.0 – +10.0
lower droplet detachment force
neutral droplet detachment force
higher droplet detachment force
harder, more stable arc
neutral arc
soft, low-spatter arc
Starting current
Start arc length correction
Starting current time
Slope 1
Slope 2
Final current
End arc length correction
SFI
SFI HotStart
Wire withdrawal
See page 98