Tps 600I - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

TPS 600i

Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Mains fuse protection
Mains voltage tolerance
Mains frequency
Cos phi (1)
Max. permissible mains impedance Z
Recommended earth-leakage circuit breaker
Welding current range (I
MIG/MAG
TIG
Rod electrode
Welding current at
Output voltage range according to standard characteristic (U
MIG/MAG
TIG
Rod electrode
Open circuit voltage (U
Degree of protection
Type of cooling
Overvoltage category
Pollution level according to IEC60664
EMC device class
Safety symbols
Dimensions l x w x h
Weight
Max. shielding gas pressure
Coolant
Max. noise emission (LWA)
1)
2)
3)
184
)
1
)
1max
)
2
10 min/40 °C (104 °F)
peak / U
0
Interface to a 230/400 V, 50 Hz public grid
Discuss the matter with the grid operator before connecting the device to the public
grid!
An emission class A device is not designed for use in residential areas supplied
with power from a public low-voltage grid.
The electromagnetic compatibility can be influenced by conducted or radiated ra-
dio frequencies.
)
1eff
1)
on PCC
max
r.m.s)
0
706 x 300 x 510 mm/27.8 x 11.8 x 20.1 in.
3 x
400 V
44.4 A
57.3 A
63 A slow-blow
+/- 15%
50/60 Hz
0.99
Possible connection
restrictions
Type B
3 - 600 A
3 - 600 A
10 - 600 A
60%
100%
600 A
500 A
)
2
14.2 - 44.0 V
10.1 - 34.0 V
20.4 - 44.0 V
74 V
IP 23
S, CE
50 kg / 100.2 lb.
7.0 bar / 101.5 psi
Original Fronius
83 dB (A)
2)
AF
III
3
3)
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tps 600iTps 500iTps 400iTps 400i lsc adv