12 Functional Descriptions
12.27.1 Parameter set switchover (up to SW 3)
a)
Spindle gear stage selection through user M function to PLC (M43 in example)
b)
Gear stage selection through programming of S value (semi-automatic)

FDD parameter sets (611D)

There is no selection of parameter sets available for feed drives. The PLC control and status
signals (DB 29, DW K + 122, bits 0 - 2; DB 29, DW K + 120, bits 0 - 2) have no effect, but
are still transferred.

MSD parameter sets (611D)

A selection of eight parameter sets is available for a main spindle drive via the PLC control
signals DB31, DW K + 74, bits 0 - 2. The active parameter set is displayed via status signals
DB 31, DW K + 72, bits 0 - 2. The MSD parameter set and NCK gear stages can be linked by
means of bit 4 in MD 522*. If the bit is reset, then the MSD parameter set is switched over
with the NCK actual gear stage. In this case, control bits DW K + 74 have no effect.
NC MD 522
12–272
More user manuals on
Part program
a)
M43
b)
M3 S1000
b)
NCK
Spindle
NCK
parameter set
SERVO
Spindle
SERVO
parameter set
MD 522*, bit 4
611D MSD
Drive
parameter set
*
. 4 is active only with 523
ManualsBase.com
Setpoint gear stage
DB 31, DR K+0, bit 0-2
DB 31, DR K+1, bit 0-2
Actual gear stage
Actual gear stage
Setpoint parameter set
DB 31, DR K+74, bit 0-2
DB 31, DR K+72, bit 0-2
Actual parameter set
*
. 0 "Extended parameter set switchover".