3Com VCX V7000 Installation And Maintenance Manual page 83

Ip telephony solution
Hide thumbs Also See for VCX V7000:
Table of Contents

Advertisement

Is this host the primary or the secondary (P/S)? [P] : s
Enter the device name of the Network Card? :eth1
Enter the device name of the Second Network Card, enter if only one? : eth0
Name of the Remote Intelligent Mirrored System?
IP Address for vcxums01 []?
IP Address for active
IP Address for standby
Is this host the primary or the secondary (P/S)? :S
VCX 7300 node configuration.
IP Address for Server vcxums02?
Does this System support SMDI? (Y/N)? [N]
Should the system use the European date order (Y/N)? [N]:
Enter the Customer name? [customer] :
Would you like to edit the file containing your selections (Y/N)?
UMS Installation Script — Secondary UMS Server (continued)
Enter s to indicate that this server is the secondary server.
All VCX servers have two network cards. When UMS is configured to run
on separate servers from the Call Processor and back end servers, it uses
both cards. To answer this question, enter the name of the second card,
eth1.
To answer this question, enter the name of the first card, eth0.
:10.20.30.44
Enter the IP address of eth0 on the primary UMS server.
The next IP addresses are the same static addresses that you entered
when configuring the primary UMS server.
[]?
:10.20.30.48
[]?
:10.20.30.49
:10.20.30.46
If the VCX system supports message waiting notification over serial lines,
press the Enter or Return key to accept the suggested answer. Otherwise,
enter y.
To use the US date order, press the Enter or Return key to accept the
suggested answer.
Optionally you can enter a customer name.
Press the Enter or Return key to accept the answers you have entered, or
enter y to see the questions again and modify one or more of your
answers.
End of UMS Installation Script — Secondary UMS Server
Installation Scripts
:vcxums01
83
[N]: