Sample Ums Installation Script (Secondary Ums Server) - 3Com VCX V7000 Installation And Maintenance Manual

Ip telephony solution
Hide thumbs Also See for VCX V7000:
Table of Contents

Advertisement

82
C
3: I
HAPTER
NSTALLATION
Sample UMS
Installation Script
(Secondary UMS
Server)
Type of VCX 7300 Installation (S-Standalone/C-Client/V-Server)? [S]
Number of voip ports? [144]
IP address of the outbound proxy? [10.20.30.41]
Name of the SIP DDD?
TCP/UDP Port on which the VCX 7300 will receive SIP messages [5060]
IP address of the primary proxy? (hit Enter if none) [ ] 10.20.30.41
Intelligent Mirroring configurations
Should Intelligent Mirroring be enabled (Y/N)?
Name of the Remote Intelligent Mirrored system? [ ] vcxums01
Intelligent Mirroring Alias? [active]
S
T
S
CRIPTS FOR
WO
ERVER
After the network installation script has been completed, the UMS
installation script starts. The sample script shown next provides guidance
on how to answer the questions.
Press the Enter or Return key to accept Standalone as the suggested
answer.
Press the Enter or Return key to accept the default number (144) of VOIP
ports that the system will support. Do not enter a different value without
consulting 3Com.
In previous releases of the VCX software the Call Processor was referred
to as the Call Proxy or Outbound Proxy. Enter the IP address of the
secondary VCX Call Processor.
[10.20.30.41]
The SIP Default Dialing Domain software runs on the same server as the
VCX Call Processor. Press the Enter or Return key to accept the IP address
of the secondary VCX Call Processor.
The VCX Call Processor and UMS both use the same port number but on
different IP addresses. Press the Enter or Return key to accept the default
port, 5060.
Enter the IP address of the primary VCX Call Processor server
(10.20.30.41 in this example configuration that contains two server
pairs).
All supported UMS configurations require Intelligent Mirroring. Enter y.
Enter the name of the active UMS server (vcxums01 in this example).
Press the Enter or Return key to accept active as the suggested answer or
enter a name of your choice. Names must be 11 characters or less.
P
AIRS
UMS Installation Script — Secondary UMS Server
[N]: y