8.1 Inspection Items

8.1.3 Replacing the Basic Unit Battery

8.1.3 Replacing the Basic Unit Battery

The Basic Unit has one replaceable built-in battery. This battery is used to back up data to prevent the data stored in the
memory from being lost when power is interrupted (e.g., when the power supply to the Basic Unit is turned OFF).
The built-in battery can retain the contents of the memory until the total time of power interruptions reaches one year.
The warranty period of the battery is five years from the date of purchase. These values, however, differ according to
the operating conditions, including the ambient temperature.
If the BAT indicator on the Basic Unit lights, replace the battery with a replacement battery (JZSP-BA01) within two
weeks. Any delay in battery replacement will result in the data stored in the memory of the Basic Unit being lost.
The appearance of the battery is illustrated below.
Note: This battery is not commercially available. Contact your Yaskawa representative.
( 1 ) Procedure
• Do not allow the battery to be replaced by anyone other than qualified personnel who have received safety
training.
Improper battery replacement can result in electric shock. It can also cause equipment malfunction, injury to operators, or
equipment damage.
• When replacing the battery, always do so with power supplied to the Basic Unit.
If power to the Basic Unit is turned OFF when the battery is replaced, data stored in the memory in the CPU Module may be
lost.
• Do not touch the battery terminals when replacing the battery.
There is a risk of electrostatic discharge failure.
• A lithium battery is built into the Controller. After replacing the battery, dispose of the old battery separate
from regular waste and in accordance with local regulations.
1.
Save the data stored in the Basic Unit to a Compact Flash, hard disk on an external computer, or other
media. This data is used to restore any data accidentally lost during battery replacement.
Note: For information on saving methods, refer to the MP900/MP2000 Series MPE720 Software for Pro-
2.
Check that the RDY indicator on the Basic Unit is lit.
3.
Open the battery cover on the unit front surface.
4.
Remove the connector on the end of lead of the built-in battery from the connector on the Basic Unit.
Then, remove the built-in battery from the battery holder.
5.
Insert securely the connector on the end of the lead of the replacement battery into the connector on
the Basic Unit. Then, insert the replacement battery into the battery holder.
6.
Check that the BAT indicator on the Basic Unit is unlit.
7.
Close the battery cover. This completes replacing the battery.
8-4
Red lead
Fig. 8.1 JZSP-BA01 (Battery with Cable)
gramming Device User's Manual (Manual No.: SIEP C880700 05).
• Battery Specifications
Type
Battery Model
LiTHIUM
Manufacturer
Nominal Voltage
Nominal Capacity
Lithium Contents
Black lead
Number Used
CAUTION
Primary lithium battery
ER3VC
Toshiba Home Appliances
3.6 V
1,000 mAh
0.3 g
1