2.5 CPU-03 Module
2.5.6 218IFA Module (Ethernet)
Message Communication Item of Connection Parameter Setting
Sets the connection parameters for the message communication using MSG-SND/MSG-RCV function and the
message communication using automatic receive function.
The following table shows each setting item.
Item
Easy Setting
CNO
(Connection Num-
ber)
Local Port
Node IP Address
Node Port
Connect Type
Protocol Type
2-46
Setting Range
Opens the Message Communication Easy Setting Dialog Box for
the connection parameters. The content of the selected connection
is displayed.
In 218IFA Ethernet communication, remote stations are distin-
guished by their connection numbers.
1 to 4
This connection number is used in remote connection number
(PARAM02) of the parameter list (PARAM) of the MSG-SND/
MSG-RCV function.
Specify the 218IFA port number for each connection. 218IFA
establishes a message communication with the connection with
this port number only. Set an unique channel number for the port
256 to 65535
number of this connections.
To delete the port number, enter zero.
Note: When the connection type = UDP, the port number cannot be
9998 or 10000.
Set the remote IP address for each connection. However, the fol-
lowing addresses are excluded:
127.xxx.xxx.xxx
xxx.xxx.xxx.000 (except 000.000.000.000)
0.0.0.0 to
xxx.xxx.xxx.255
255.255.255.254
Note: When 0.0.0.0 is set, it will enter into "Unpassive open
mode." When 218IFA is within the network specified by the
subnet mask, it responds to the connection request from the
remote station regardless of the remote IP address setting.
Specify the remote port number for each connection. A pair of
0 and
remote IP address and remote port number must not be duplicated.
256 to 65535
Note: In case of "Unpassive open mode," set it to zero.
Select a transport layer protocol.
TCP,
TCP: Transmission control protocol
UDP
UDP: User datagram protocol
Select an application layer protocol.
Protocol Type
Extended
MEMOBUS
Extended
MEMOBUS
MEMOBUS,
MEMOBUS,
MELSEC
MELSEC,
None,
MODBUS/TCP
Non-procedure
MODBUS/TCP
Details
Overview
Yaskawa's Extended MEMOBUS protocol.
Yaskawa's MEMOBUS protocol.
Ethernet I/F protocol for the sequencer (A
series) manufactured by Mitsubishi Elec-
tric Corporation.
General-purpose message communication.
Transmits and receives continuous data
intact in the specified register.
Industrial Ethernet protocol proposed by
Modicon, Inc.
Default
0
000.000.000.0
00
0
TCP
Extended
MEMOBUS