4.2.2 Self Configuration
Run the self configuration to automatically recognize devices connected to the MECHATROLINK connector.
Steps for self configuration are as follows.
1.
Check that the Σ-III SERVOPACK power supply is ON.
2.
Turn OFF the 100-VAC power supply to the MP2200.
3.
Set the INIT and CNFG pins on the DIP switch (SW1) to ON on the MP2200.
4.
Turn ON the 100-VDC power supply to the MP2200, and confirm that the indicators change as follows:
MP2200
BATTEY
100 VAC
AC
5.
Self configuration is complete, and MECHATROLINK slave device information has been written to a
definition information file.
6.
Set the INIT and CNFG pins on the DIP switch (SW1) to OFF on the MP2200.
CPU-01
218F-01
SVB-01
MBU-01
POWER
PORT
M- /
CN1
100/200V
10Base-T
CN2
POWER
4.2.2 Self Configuration
RDY
RUN
RDY
RUN
ALM
ERR
ALM
ERR
BAT
BAT
STOP
SUP
INIT
SW1
CNFG
MON
TEST
ON
4.2 Preparation
RDY
RUN
ALM
ERR
BAT
:Lit
:Not lit
:Blinking
4