2.5 CPU-03 Module
2.5.6 218IFA Module (Ethernet)
In addition, click the Default Button to set the default values for data code type, local I/O register setting, read/write
size, and node read/write register setting according to the selected communication protocol type.
The following table provides these default values.
Communication
Protocol Type
Extended
MEMOBUS
MEMOBUS
MELSEC
MODBUS/TCP
2-54
Data Code
Local Input/Output Register Setting
Type
IW
to IW
BIN
OW
+ 4 to OW
(output)
RTU
Same as above
BIN
Same as above
BIN
Same as above
Default
Read/Write Size
+ 3 (input)
4 (read)
+7
4 (write)
Same as above
Same as above
Same as above
Node Read/Write Register
Setting
MW0000 to MW0003 (read)
MW0004 to MW0007 (write)
Same as above
D0000 to D0003 (read)
D0004 to D0007 (write)
4X00001 to 4X0004 (read)
4X00005 to 4X0008 (write)