Parameter list setting example for message receive function
An example of a parameter list setting when receiving messages from a transmit source using the connection with
connection numbers = 5 and 6 follows:
Table 6.10 Parameter List Setting Example 1 (parameter list start address Param = DA00000)
Register
Setting
Number
Value
DW00000
DW00001
00005
DW00002
DW00003
DW00004
DW00005
DW00006
DW00007
00000
DW00008
00000
DW00009
00000
DW00010
00000
DW00011
00000
DW00012
65534
DW00013
DW00014
DW00015
DW00016
Note: IN: Input, OUT: Output, SYS: For system use
Table 6.11 Parameter List Setting Example 2 (parameter list start address Param = DA00000)
Register
Setting
Number
Value
DW00000
DW00001
00006
DW00002
DW00003
DW00004
DW00005
DW00006
DW00007
00000
DW00008
00000
DW00009
00000
DW00010
00000
DW00011
00000
DW00012
65534
DW00013
DW00014
DW00015
DW00016
Note: IN: Input, OUT: Output, SYS: For system use
6.2.3 When CPU-03/CPU-04 Acts as Master (I/O message communication function is used)
Parameter
IN/OUT
Number
PARAM00
OUT
PARAM01
OUT
PARAM02
IN
PARAM03
OUT
PARAM04
OUT
PARAM05
OUT
PARAM06
OUT
PARAM07
OUT
PARAM08
IN
PARAM09
IN
PARAM10
IN
PARAM11
IN
PARAM12
IN
PARAM13
IN
PARAM14
SYS
PARAM15
SYS
PARAM16
SYS
Parameter
IN/OUT
Number
PARAM00
OUT
PARAM01
OUT
PARAM02
IN
PARAM03
OUT
PARAM04
OUT
PARAM05
OUT
PARAM06
OUT
PARAM07
OUT
PARAM08
IN
PARAM09
IN
PARAM10
IN
PARAM11
IN
PARAM12
IN
PARAM13
IN
PARAM14
SYS
PARAM15
SYS
PARAM16
SYS
6.2 Communication with Other MP Series
Remarks
Process result
Status
Connection number = 5 (For receiving read operation)
Option
Function code
Data address
Data size
Remote CPU number
Coil offset = 0 word
Input relay offset = 0 word
Input register offset = 0 word
Holding register offset = 0 word
Writable address lower limit = MW00000
Writable address upper limit = MW65534
Reserved by the system. (Zero clear at startup)
Reserved by the system.
Reserved by the system.
Remarks
Process result
Status
Connection number = 6 (For receiving write opera-
tion)
Option
Function code
Data address
Data size
Remote CPU number
Coil offset = 0 word
Input relay offset = 0 word
Input register offset = 0 word
Holding register offset = 0 word
Writable address lower limit = MW00000
Writable address upper limit = MW65534
Reserved by the system. (Zero clear at startup)
Reserved by the system.
Reserved by the system.
6
6-43