Configure the maximum number of CCSS agents which may be allocated for this
CC Max Agents
channel. In other words, this number serves as the maximum number of CC requests
this channel can make. The minimum value is 1.
Configure the maximum number of monitor structures which may be created for this
CC Max Monitors
device. In other words, this number tells how many callers may request CC services
for a specific device at one time. The minimum value is 1.
Ring Simultaneously
Enable this option to have an external number ring simultaneously along with the
Ring
extension. If a register trunk is used for outbound, the register number will be used to
Simultaneously
be displayed for the external number as caller ID number.
Set the external number to be rang simultaneously. '-' is the connection character
External Number
which will be ignored.
Time Condition for
Ring the external number simultaneously along with the extension on the basis of this
Ring
time condition.
Simultaneously
Use callee DOD on
Use the DOD number when calls are being diverted/forwarded to external
FWD or Ring
destinations or when ring simultaneous is configured.
Simultaneously
Monitor privilege control
Allowed to
Add members from "Available Extensions" to "Selected Extensions" so that the
call-barging
selected extensions can spy on the used extension using feature code.
Seamless transfer privilege control
Any extensions on the UCM can perform seamless transfer. When using Pickup Incall
Allowed to
feature, only extensions available on the "Selected Extensions" list can perform
seamless transfer
seamless transfer to the edited extension.
Other Settings
Configure the number of seconds to ring the user before the call is forwarded to
voicemail (voicemail is enabled) or hang up (voicemail is disabled). If not specified,
the default ring timeout is 60 seconds on the UCM6200, which can be configured in
the
Ring Timeout
PromptCustom Prompt: General Preference. The valid range is between 5 seconds
and 600 seconds.
Note: If the end point also has a ring timeout configured, the actual ring timeout used
is the shortest time set by either device.
global
ring
timeout
setting