Function
Name
code
P17.09
Output torque
P17.11
DC bus voltage
Switch input
P17.12
terminals state
Switch output
P17.13
terminals state
Digital
P17.14
adjustment
P17.18
Counting value
AI1 input
P17.19
voltage
AI2 input
P17.20
voltage
PID reference
P17.23
value
PID response
P17.24
value
Power factor of
P17.25
the motor
Function Parameters
Detailed instruction of parameters
Display the current output torque of the inverter.
Range: -250.0~250.0%
Display current DC bus voltage of the inverter
Range: 0.0~2000.0V
Display current Switch input terminals state of the inverter
Range: 0000~00FF
Display current Switch output terminals state of the inverter
Range: 0000~000F
Display the adjustment through the keypad of the inverter.
Range : 0.00Hz~P00.03
Display the current counting number of the inverter.
Range: 0~65535
Display analog AI1 input signal.
Range: 0.00~10.00V
Display analog AI2 input signal. Range: 0.00~10.00V
Display PID reference value. Range: -100.0~100.0%
Display PID response value. Range: -100.0~100.0%
Display the current power factor of the motor. Range:
-1.00~1.00
Default
Modify
value
0.0%
0V
0
0
0.00Hz
0
0.00V
0.00V
0.0%
0.0%
0
65 - 104