Salicru CV10-002-S2 User Manual page 35

Controlvit cv10 series
Table of Contents

Advertisement

Function
Name
code
Motor V/F slip
P04.09
compensation
gain
Low frequency
P04.10
vibration
control factor
High frequency
P04.11
vibration
control factor
Vibration
P04.12
control
threshold
Energy-saving
P04.26
operation
S1 terminal
P05.01
function
selection
S2 terminal
P05.02
function
Function Parameters
Detailed instruction of parameters
This function code is used to compensate the change of the
rotation speed caused by load during compensation
SVPWM control to improve the rigidity of the motor. It can be
set to the rated slip frequency of the motor which is counted
as below:
△ f = f
-n*p/60
b
Of which, f
is the rated frequency of the motor, its function
b
code is P02.02; n is the rated rotating speed of the motor
and its function code is P02.03; p is the pole pair of the
motor. 100.0% corresponds to the rated slip frequency △ f.
Note: no torque compensation for single-phase 230V
inverters
Setting range: 0.0~200.0%
In the SVPWM control mode, current fluctuation may occur
to the motor on some frequency, especially the motor with
big power. The motor can not run stably or overcurrent may
occur. These phenomena can be canceled by adjusting this
parameter.
The setting range of P04.10: 0~100
The setting range of P04.11: 0~100
The setting range of P04.12:0.00Hz~P00.03 (the Max.
frequency)
0: No operation
1: Automatic energy-saving operation
Motor on the light load conditions, automatically adjusts the
output voltage to save energy
P05 Group Input terminals
0: No function
1: Forward rotation operation
2: Reverse rotation operation
3: 3-wire control operation
4: Forward rotation jogging
Default
Modify
value
0%
10
10
30.00 Hz
0
1
4
35 - 104

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cv10-004-s2Cv10-008-s2Cv10-015-s2Cv10-022-s2

Table of Contents