Function
Name
code
Ramp reference
P07.50
frequency at the
previous 2 faults
Output voltage
P07.51
at the previous
2 faults
Output current
P07.52
at the previous
2 faults
Bus voltage at
P07.53
the previous 2
faults
Max.
P07.54
temperature at
previous 2 faults
Input terminals
P07.55
state at previous
2 faults
Output terminals
P07.56
state at previous
2 faults
P08.00
ACC time 2
P08.01
DEC time 2
Jogging
P08.06
running
frequency
Function Parameters
Detailed instruction of parameters
P08 Group Enhanced function
Refer to P00.11 and P00.12 for detailed definition.
CV10 inverters define four groups of ACC/DEC time which
can be selected by P5 group. The first group of ACC/DEC
time is the factory default one.
Setting range:0.0~3600.0s
This parameter is used to define the reference frequency
during jogging.
Setting range: 0.00Hz ~P00.03(the Max. frequency)
Default
Modify
value
●
0.00Hz
●
0V
●
0.0A
●
0.0V
●
0.0
●
0
●
0
Depends
○
on model
Depends
○
on model
○
5.00Hz
49 - 104