Function
Name
code
Communication
P14.06
processing
action selection
P17.00
Set frequency
Output
P17.01
frequency
Ramp
P17.02
reference
frequency
P17.03
Output voltage
P17.04
Output current
P17.05
Motor speed
P17.08
Motor power
64 - 104
Detailed instruction of parameters
0x00~0x11
LED ones:
0: Operation with response. The drive will respond to all
reading and writing commands of the upper monitor.
1: Operation without response. The drive only responds to
the reading command other than the writing command of the
drive. The communication efficiency can be increased by this
method.
LED tens: (reserved)
P17 Group
Monitoring function
Display current set frequency of the inverter
Range: 0.00Hz~P00.03
Display current output frequency of the inverter
Range: 0.00Hz~P00.03
Display current ramp reference frequency of the inverter
Range: 0.00Hz~P00.03
Display current output voltage of the inverter
Range: 0~1200V
Display current output current of the inverter
Range: 0.0~5000.0A
Display the rotation speed of the motor.
Range: 0~65535RPM
Display current power of the motor.
Setting range: -300.0%~300.0% (the rated current of the
motor)
Default
Modify
value
0x00
0.00Hz
0.00Hz
0.00Hz
0V
0.0A
0 RPM
0.0%