Function
Name
code
Digital output
P06.01
selection (Y)
Relay RO
P06.03
output
Polarity of
P06.05
output
terminals
Y open delay
P06.06
time
P06.07
Y off delay time 0.000~50.000s
Function Parameters
Detailed instruction of parameters
P06 Group
0: Invalid
1: On operation
2: Forward rotation operation
3: Reverse rotation operation
4: Jogging operation
5: Inverter fault
6: Frequency degree test FDT1
7: Frequency degree test FDT2
8: Frequency arrival
9: Zero speed running
10: Upper limit frequency arrival
11: Lower limit frequency arrival
12: Ready for operation
14: Overload pre-alarm
15: Underload pre-alarm
16: Completion of simple PLC stage
17: Completion of simple PLC cycle
18: Setting count value arrival
19: Defined count value arrival
20: External fault
22: Running time arrival
23: MODBUS communication virtual terminals output
24 ~ 30: Reserved
The function code is used to set the pole of the output
terminal.
When the current bit is set to 0, output terminal is positive.
When the current bit is set to 1, output terminal is negative.
BIT3
BIT2
Reserved
RO1
Setting range:00~0F
0.000~50.000s
Output terminals
BIT1
Reserved
Default
value
0
1
00
BIT0
Y
0.000s
0.000s
Modify
41 - 104