B.3 Parameter Table
 d: References
Reference parameters are used to set the various frequency reference values during operation.
d1: Frequency Reference
No.(Addr.)
Name
d1-01
(280H)
Frequency Reference 1
d1-02
(281H)
Frequency Reference 2
d1-03
(282H)
Frequency Reference 3
d1-04
(283H)
Frequency Reference 4
d1-05
(284H)
Frequency Reference 5
d1-06
(285H)
Frequency Reference 6
d1-07
(286H)
Frequency Reference 7
d1-08
(287H)
Frequency Reference 8
d1-09
(288H)
Frequency Reference 9
d1-10
(28BH)
Frequency Reference 10
d1-11
(28CH)
Frequency Reference 11
d1-12
(28DH)
Frequency Reference 12
d1-13
(28EH)
Frequency Reference 13
d1-14
(28FH)
Frequency Reference 14
d1-15
(290H)
Frequency Reference 15
d1-16
(291H)
Frequency Reference 16
d1-17
(292H)
Jog Frequency Reference
<20> Range upper limit is determined by the maximum output frequency (E1-04) and the upper limit of the frequency reference (d2-01).
<63> The value of o1-03 is changed to 1 and the unit is also changed to a percentage (%) when the control mode is set to CLV/PM or AOLV/PM.
466
All Modes
Sets the frequency reference for the drive. Setting units are determined by parameter o1-03.
Note: The value set to o1-03 is changed to 1 and the unit is changed to percentage automatically
when A1-02 is set to 6 or 7
All Modes
Sets the jog frequency reference. Setting units are determined by parameter o1-03.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Description
Setting
Page
198
198
198
198
198
198
198
198
Default: 0.00 Hz
Min: 0.00 Hz
Max: 400.00 Hz
<20> <63>
198
198
198
198
198
198
198
198
Default: 6.00 Hz
Min: 0.00 Hz
198
Max: 400.00 Hz
<20> <63>