B.2 Parameter Groups
 Parameter Differences for models CIMR-A4A0930 and 4A1200
Parameter Group
A1
Initialization Parameters
b1
Operation Mode Selection
b2
DC Injection Braking and Short Circuit Braking
b3
Speed Search
b4
Timer Function
b5
PID Control
b8
Energy Saving
C3
Slip Compensation
C5
Automatic Speed Regulator (ASR)
C6
Carrier Frequency
E2
Motor 1 Parameters
E4
Motor 2 Parameters
E5
PM Motor Settings
F1
PG Speed Control Card (PG-B3/PG-X3/PG-RT3/PG-F3) F1-50 to F1-53 are not available in models CIMR-A4A0930 and 4A1200.
H2
Multi-Function Digital Outputs
H3
Multi-Function Analog Inputs
H5
MEMOBUS/Modbus Serial Communication
L1
Motor Protection
L3
Stall Prevention
L8
Drive Protection
L9
Drive Protection 2
n8
PM Motor Control Tuning
T1
Induction Motor Auto-Tuning
T2
PM Motor Auto-Tuning
U1
Operation Status Monitors
U2
Fault Trace
U4
Maintenance Monitors
452
Name
The setting range of A1-00 is 0 to 7. Refer to
b1-21 is not available in models CIMR-A4A0930 and 4A1200.
b2-02, b2-03, and b2-04 are not available for OLV/PM in models CIMR-A4A0930 and 4A1200.
• b3-04 is available in V/f and OLV. Refer to
• b3-07, b3-12, and b3-26 are available in models CIMR-A4A0930 and 4A1200.
• b3-29 and b3-33 are not available in models CIMR-A4A0930 and 4A1200.
b4-03 to b4-08 are not available in models CIMR-A4A0930 and 4A1200.
The setting range of b5-01 is 0 to 4.
b8-27 is not available in models CIMR-A4A0930 and 4A1200.
• C3-05 is available in OLV, CLV, AOLV/PM, or CLV/PM (A1-02 = 2, 3, 6, 7). Refer to
Compensation on page 462
• C3-16 to C3-18 are available in models CIMR-A4A0930 and 4A1200.
C5-39 is not available in models CIMR-A4A0930 and 4A1200.
• The setting range of C6-02 is 1, 2, or F.
• The setting range of C6-03 and C6-04 is 1.0 to 5.0 Hz. Refer to
details.
• C6-09 is not available in models CIMR-A4A0930 and 4A1200.
For E2-05, the setting unit is m and the setting range is 0.000 m to 65.000 m. Refer to
Parameters on page 470
For E4-05, the setting unit is m and the setting range is 0.000 m to 65.000 m. Refer to
Parameters on page 472
E5-25 is available in OLV/PM, AOLV/PM, or CLV/PM (A1-02 = 5, 6, 7). Refer to
Settings on page
• H2-07 to H2-10 are not available in models CIMR-A4A0930 and 4A1200.
• H2- cannot be set to D, 4E, 4F, 62, or 63.
H3- = 17 is available in models CIMR-A4A0930 and 4A1200.
H5-18 are not available in models CIMR-A4A0930 and 4A1200.
• L1-08 and L1-09 are not available in models CIMR-A4A0930 and 4A1200.
• L1-15 to L1-20 are available in models CIMR-A4A0930 and 4A1200.
• L3-04 cannot be set to 3.
• L3-34 and L3-35 are not available in models CIMR-A4A0930 and 4A1200.
• L8-01 and L8-55 are not available.
• The setting range of L8-29 is 0 or 1.
• L8-78 is available.
L9-03 is not available in models CIMR-A4A0930 and 4A1200.
• n8-03, n8-04, n8-11 to n8-21, n8-36 to n8-39, and n8-72 are not available in models CIMR-A4A0930
and 4A1200.
• n8-02 is not available in CLV/PM control mode in models CIMR-A4A0930 and 4A1200.
The setting range of T1-01 is 0 to 4, 8, or 9.
The setting range of T2-01 is 0 to 11.
• The setting units of U1-03 is 1 A. Refer to
• U1-29 is available in models CIMR-A4A0930 and 4A1200.
• The setting units of U2-05 is 1 A. Refer to
• U2-27 and U2-28 are available in models CIMR-A4A0930 and 4A1200.
• The setting units of U4-13 is 1 A. Refer to
• U4-32, U4-37, U4-38, and U4-39 are available in models CIMR-A4A0930 and 4A1200.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Difference
A1: Initialization Parameters on page
b3: Speed Search on page 456
for details.
for details.
for details.
473.
U1: Operation Status Monitors on page 510
U2: Fault Trace on page 512
U4: Maintenance Monitors on page 514
453.
for details.
C3: Slip
C6: Carrier Frequency on page 465
for
E2: Motor 1
E4: Motor 2
E5: PM Motor
for details.
for details.
for details.

Hide quick links: