No.
Model CIMR-A
C6-01
Drive Duty Selection
o2-04
Drive Model Selection
E2-11 (E4-11)
Motor rated Output
Current Control Gain during Speed Search (Speed
b3-08
Estimation Type)
b3-26
Start Speed Search Select
<66>
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17 (C5-37)
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01 (E4-01)
Motor Rated Current
E2-02 (E4-02)
Motor Rated Slip
E2-03 (E4-03)
Motor No-Load Current
E2-05 (E4-05)
Motor Line to Line Resistance
E2-06 (E4-06)
Motor Leakage Inductance
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
E5-01
Motor Code Selection (for PM Motors)
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
n5-02
Motor Acceleration Time
<66> This parameter is available in models CIMR-A4A0930 and 4A1200.
No.
Model CIMR-A
C6-01
Drive Duty Selection
o2-04
Drive Model Selection
E2-11 (E4-11)
Motor rated Output
b3-04
V/f Gain during Speed Search
b3-06
Output Current 1 during Speed Search
Output Current 2 during Speed Search (Speed
b3-07
<66>
Estimation Type)
Current Control Gain during Speed Search (Speed
b3-08
Estimation Type)
b3-26
Start Speed Search Select
<66>
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17 (C5-37)
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01 (E4-01)
Motor Rated Current
E2-02 (E4-02)
Motor Rated Slip
E2-03 (E4-03)
Motor No-Load Current
E2-05 (E4-05)
Motor Line to Line Resistance
E2-06 (E4-06)
Motor Leakage Inductance
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
E5-01
Motor Code Selection (for PM Motors)
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
n5-02
Motor Acceleration Time
<66> This parameter is available in models CIMR-A4A0930 and 4A1200.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
B.6 Defaults by Drive Model Selection (o2-04) and ND/HD (C6-01)
Name
Unit
Hex.
kW
s
2
kgm
A
Hz
A
%
W
Hex.
s
s
s
s
C
ms
s
Name
Unit
Hex.
kW
%
s
kgm
2
A
Hz
A
%
W
Hex.
s
s
s
s
C
ms
s
Default Settings
4A0362
HD
ND
HD
0
1
0
A9
160
185
185
0.8
0.8
0.8
2.00
2.00
2.00
30.13
30.57
30.57
3.30
3.60
3.60
1
7
1
270
310
310
1.35
1.3
1.3
70
81
81
0.029
0.025
0.025
20
20
20
2850
3200
3200
124A
124A
FFFF
2
2
2
1.8
1.9
1.9
1
1
1
0.777
0.864
0.864
130
130
140
0
0
0
2
2
2
30
30
100
0.777
0.864
0.864
Default Settings
4A0675
HD
ND
HD
0
1
0
AE
315
355
450
60
60
60
0.7
0.7
0.7
3.0
0.8
0.8
0.8
1000
2.00
2.00
2.00
21.76
23.84
21.4
11.00
12.00
13.00
1
7
1
500
650
800
1.25
1
1
130
130
160
0.014
0.012
0.01
20
20
20
4700
5560
7050
FFFF
FFFF
FFFF
2
2
2
2.1
2.3
2.8
1
1
2.6
1.392
1.667
2
140
140
140
0
0
0
2
2
2
100
100
100
1.392
1.667
2
4A0414
4A0515
ND
HD
1
0
AA
AC
220
220
0.8
0.8
2.00
2.00
27.13
27.13
4.10
4.10
7
1
370
370
1.3
1.3
96
96
0.02
0.02
20
20
3700
3700
FFFF
FFFF
2
2
2
2
1
1
0.91
0.91
140
140
0
0
2
2
100
100
0.91
0.91
4A0930
4A1200
ND
HD
1
0
B0
B2
500
560
60
60
0.7
0.7
2.0
3.0
0.8
0.8
1000
1000
2.00
2.00
20.26
18.12
14.00
18.00
1
1
900
1090
0.9
0.8
180
218
0.009
0.007
20
20
7833
9870
FFFF
FFFF
2
2
3.1
4
3
3.8
2.222
2.857
140
140
0
0
2
2
100
100
2.222
2.857
ND
1
250
0.8
2.00
21.76
6.50
7
500
1.25
130
0.014
20
4700
FFFF
2
2.1
1
1.392
140
0
2
100
1.392
ND
1
630
60
0.7
2.0
0.8
1000
2.00
17.06
18.00
1
1200
0.7
240
0.006
20
11123
FFFF
2
4.6
4.5
3.333
140
0
2
B
100
3.333
529

Hide quick links: