YASKAWA A1000 Technical Manual page 477

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

No.(Addr.)
Name
F4-05
(395H)
Terminal V1 Monitor Bias
F4-06
(396H)
Terminal V2 Monitor Bias
F4-07
Terminal V1 Signal Level
(397H)
F4-08
Terminal V2 Signal Level
(398H)
F5: Digital Output Card (DO-A3)
No.(Addr.)
Name
F5-01
Terminal P1-PC Output Selection
(399H)
F5-02
Terminal P2-PC Output Selection
(39AH)
F5-03
Terminal P3-PC Output Selection
(39BH)
F5-04
Terminal P4-PC Output Selection
(39CH)
F5-05
Terminal P5-PC Output Selection
(39DH)
F5-06
Terminal P6-PC Output Selection
(39EH)
F5-07
Terminal M1-M2 Output Selection
(39FH)
F5-08
Terminal M3-M4 Output Selection
(3A0H)
F5-09
DO-A3 Output Mode Selection
(3A1H)
F6: Communication Option Card (SI-C3, SI-EM3, SI-EN3, SI-ET3, SI-N3, SI-P3, SI-S3, SI-T3,
and SI-W3)
F6-01 through F6-03, F6-06 through F6-08, F6-14, and F7-16 are common settings used for CC-Link, CANopen,
DeviceNet, Ethernet/IP, PROFIBUS-DP, MECHATROLINK-II, MECHATROLINK-III, Modbus TCP/IP, and
LONWORKS option cards. Other parameters in the F6 group are used for communication protocol specific settings.
For more details on a specific option card, refer to the instruction manual for the option card.
No.(Addr.)
Name
F6-01
Communications Error Operation
(3A2H)
Selection
F6-02
External Fault from Comm. Option
(3A3H)
Detection Selection
F6-03
External Fault from Comm. Option
(3A4H)
Operation Selection
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
All Modes
Sets the amount of bias added to the voltage output via terminal V1.
All Modes
Sets the amount of bias added to the voltage output via terminal V2.
All Modes
0: 0 to 10 V
1: -10 to 10 V
All Modes
Sets the function for contact output terminals M1-M2, M3-M4, and photocoupler output
terminals P1 through P6.
All Modes
0: Output terminals are each assigned separate output functions.
1: Binary code output
2: Use output terminal functions selected by parameters F5-01 through F5-08.
All Modes
0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration time in C1-09.
3: Alarm only.
4: Alarm and Run at d1-04
5: Alarm and Ramp to stop (automatic recovery)
Note: Take proper safety measures, such as installing an emergency stop switch, when setting
F6-01 to 3 or 4.
All Modes
0: Always detected
1: Detection during run only
All Modes
0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration time in C1-09.
3: Alarm only.
Description
Description
Description
B.3 Parameter Table
Setting
Page
Default: 0.0%
Min: -999.9%
230
Max: 999.9%
Default: 0.0%
Min: -999.9%
230
Max: 999.9%
Default: 0
Min: 0
230
Max: 1
Default: 0
Min: 0
230
Max: 1
Setting
Page
Default: 0
Min: 0
231
Max: 192
Default: 1
Min: 0
231
Max: 192
Default: 2
Min: 0
231
Max: 192
Default: 4
Min: 0
231
Max: 192
Default: 6
Min: 0
231
Max: 192
Default: 37
Min: 0
231
Max: 192
Default: F
Min: 0
231
Max: 192
Default: F
Min: 0
231
Max: 192
Default: 0
Min: 0
231
Max: 2
Setting
Page
Default: 1
Min: 0
232
Max: 5
Default: 0
Min: 0
232
Max: 1
Default: 1
Min: 0
232
Max: 3
477
B