Setting 5: Compressor Application - YASKAWA A1000 Technical Manual

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

4.6 Application Selection
 Setting 5: Compressor Application
No.
A1-02
Control Method Selection
b1-04
Reverse Operation Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Duty Rating
E1-03
V/f Pattern Selection
L2-01
Momentary Power Loss Operation Selection
L3-04
Stall Prevention Selection during Deceleration
No.
b1-01
Frequency Reference Selection
b1-02
Run Command Selection
b1-04
Reverse Operation Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
 Setting 6: Hoist Application
Note: 1. Read the instructions listed on page
2. Perform Auto-Tuning after selecting the Hoist Application Preset.
No.
A1-02
Control Method Selection
b1-01
Frequency Reference Selection
b6-01
Dwell Reference at Start
b6-02
Dwell Time at Start
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Duty Rating
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
d1-02
Frequency Reference 2
d1-03
Frequency Reference 3
E1-03
V/f Pattern Selection
H2-01
Terminals M1-M2 Function Selection
H2-02
Terminals M3-M4 Function Selection
H3-06
Terminal A3 Function Selection
L2-03
Momentary Power Loss Minimum Baseblock Time
L3-04
Momentary Power Loss Voltage Recovery Ramp Time
L4-01
Speed Agreement Detection Level
L4-02
Speed Agreement Detection Width
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L8-05
Input Phase Loss Protection Selection
L8-07
Output Phase Loss Protection Selection
L8-38
Carrier Frequency Reduction
L8-41
Current Alarm Selection
<1> This parameter is not available in drive models CIMR-A4A0930 and 4A1200
No.
A1-02
Control Method Selection
b1-01
Frequency Reference Selection
b6-01
Dwell Reference at Start
b6-02
Dwell Time at Start
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
116
Table 4.14 Compressor: Parameter Settings
Parameter Name
Table 4.15 Compressor: User Parameters (A2-01 to A2-16):
Parameter Name
117
when using Hoist Application Preset
Table 4.16 Hoist: Parameters and Settings
Parameter Name
<1>
Table 4.17 Hoist: User Parameters (A2-01 to A2-16):
Parameter Name
0: V/f Control
1: Reverse Prohibited
5.0 s
5.0 s
0: Heavy Duty (HD)
F: V/f Pattern Selection
1: Enabled
1: Enabled
No.
E1-03
V/f Pattern Selection
E1-07
Mid Output Frequency
E1-08
Mid Output Frequency Voltage
E2-01
Motor Rated Current
2: Open Loop Vector Control
0: Operator
3.0 Hz
0.3 s
3.0 s
3.0 s
0: Heavy Duty (HD)
2: 5 kHz
6.0 Hz
30.0 Hz
50. 0 Hz
F: V/f Pattern Selection
5: Frequency Detection 2
37: During Frequency Output
1F: Through mode
0.3 s
0: Disabled
2.0 Hz
0.0 Hz
8: UL3 at RUN - Fault
2%
0.5 s
1: Enabled
1: Enabled
1: Enabled below 6 Hz
1: Enabled (alarm is output)
No.
d1-02
Frequency Reference 2
d1-03
Frequency Reference 3
E1-08
Mid Output Frequency Voltage
H2-01
Terminals M1-M2 Function Selection
L1-01
Motor Overload Protection Selection
L4-01
Speed Agreement Detection Level
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Default Setting
Parameter Name
Default Setting
Parameter Name