YASKAWA A1000 Technical Manual page 487

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

H2-
Function
Setting
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-set Speed Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive Ready
7
DC bus Undervoltage
8
During Baseblock (N.O.)
9
Frequency Reference Source
A
Run Command Source
B
Torque Detection 1 (N.O.)
C
Frequency Reference Loss
D
Braking Resistor Fault
E
Fault
F
Through Mode
10
Minor Fault
11
Fault Reset Command Active
12
Timer Output
13
Speed Agree 2
14
User-set Speed Agree 2
15
Frequency Detection 3
16
Frequency Detection 4
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
H2 Multi-Function Digital Output Settings
All Modes
Closed: A Run command is active or voltage is output.
All Modes
Open: Output speed is greater than or equal to the value of E1-09 (Minimum Output Frequency) or b2-01 (DC Injection
Braking Start Frequency).
Closed: Output frequency is less than the value of E1-09 (Minimum Output Frequency) or b2-01 (DC Injection Braking
Start Frequency).
All Modes
Closed: Output frequency equals the speed reference (plus or minus the hysteresis set to L4-02).
All Modes
Closed: Output frequency and speed reference equal L4-01 (plus or minus the hysteresis set to L4-02).
All Modes
Closed: Output frequency is less than or equal to the value in L4-01 with hysteresis determined by L4-02.
All Modes
Closed: Output frequency is greater than or equal to the value in L4-01 with hysteresis determined by L4-02.
All Modes
Closed: Power up is complete and the drive is ready to accept a Run command.
All Modes
Closed: DC bus voltage is below the Uv trip level set in L2-05.
All Modes
Closed: Drive has entered the baseblock state (no output voltage).
All Modes
Open: External Reference 1 or 2 supplies the frequency reference (set in b1-01 or b1-15).
Closed: Digital operator supplies the frequency reference.
All Modes
Open: External Reference 1 or 2 supplies the Run command (set in b1-02 or b1-16).
Closed: Digital operator supplies the Run command.
All Modes
Closed: An overtorque or undertorque situation has been detected.
All Modes
Closed: Analog frequency reference has been lost.
Frequency reference loss is detected when the frequency reference drops below 10% of the reference within 400 ms.
All Modes
Closed: Braking resistor or transistor is overheated or faulted out.
Note: This set value is not available in models CIMR-A4A0930 and 4A1200.
All Modes
Closed: Fault occurred (this excludes faults CPF00 and CPF01).
All Modes
Select this setting when the terminal is not used or when using the terminal in the pass-through mode.
All Modes
Closed: An alarm has been triggered, or the IGBTs have reached 90% of their expected life span.
All Modes
Closed: The drive has received a reset command from the multi-function input terminals or from serial network, or the
digital operator's RESET key has been pressed.
All Modes
Closed: Timer output.
All Modes
Closed: When drive output frequency equals the frequency reference ±L4-04.
All Modes
Closed: When the drive output frequency is equal to the value in L4-03 ±L4-04.
All Modes
Closed: When the drive output frequency is less than or equal to the value in L4-03 ±L4-04.
All Modes
Closed: When the output frequency is greater than or equal to the value in L4-03 ±L4-04.
Description
B.3 Parameter Table
Page
246
247
247
248
248
249
249
249
249
249
250
250
250
250
250
250
250
250
250
251
251
252
252
487