YASKAWA A1000 Technical Manual page 525

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

No.
Model CIMR-A
C6-01
Drive Duty Selection
o2-04
Drive Model Selection
E2-11 (E4-11)
Motor rated Output
C5-17 (C5-37)
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01 (E4-01)
Motor Rated Current
E2-02 (E4-02)
Motor Rated Slip
E2-03 (E4-03)
Motor No-Load Current
E2-05 (E4-05)
Motor Line to Line Resistance
E2-06 (E4-06)
Motor Leakage Inductance
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
E5-01
Motor Code Selection (for PM Motors)
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
n5-02
Motor Acceleration Time
<66> This parameter is available in models CIMR-A4A0930 and 4A1200.
No.
Model CIMR-A
C6-01
Drive Duty Selection
o2-04
Drive Model Selection
E2-11 (E4-11)
Motor rated Output
b3-04
V/f Gain during Speed Search
b3-06
Output Current 1 during Speed Search
Output Current 2 during Speed Search (Speed
b3-07
<66>
Estimation Type)
Current Control Gain during Speed Search (Speed
b3-08
Estimation Type)
b3-26
Start Speed Search Select
<66>
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17 (C5-37)
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01 (E4-01)
Motor Rated Current
E2-02 (E4-02)
Motor Rated Slip
E2-03 (E4-03)
Motor No-Load Current
E2-05 (E4-05)
Motor Line to Line Resistance
E2-06 (E4-06)
Motor Leakage Inductance
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
E5-01
Motor Code Selection (for PM Motors)
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
n5-02
Motor Acceleration Time
<66> This parameter is available in models CIMR-A4A0930 and 4A1200.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
B.6 Defaults by Drive Model Selection (o2-04) and ND/HD (C6-01)
Name
Unit
Hex.
kW
2
kgm
A
Hz
A
%
W
Hex.
s
s
s
s
C
ms
s
Name
Unit
Hex.
kW
%
s
2
kgm
A
Hz
A
%
W
Hex.
s
s
s
s
C
ms
s
Default Settings
2A0169
HD
ND
HD
0
1
0
73
37
45
45
0.273
0.333
0.333
1
7
1
131
160
160
1.33
1.6
1.6
38.2
44
44
0.039
0.03
0.03
18.8
20.2
20.2
823
852
852
1213
1213
1214
2
2
2
1.1
1.2
1.2
0.6
1
1
0.32
0.387
0.387
130
130
125
0
0
0
2
2
2
10
10
10
0.32
0.387
0.387
Default Settings
2A0312
HD
ND
HD
0
1
0
76
75
90
90
80
80
80
0.7
0.7
0.7
0.5
0.5
0.5
2.00
2.00
2.00
23.1
20.65
20.65
0.90
1.10
1.10
1
7
1
260
260
260
1.39
1.39
1.39
72
72
72
0.023
0.023
0.023
20
20
20
1200
1200
1200
1216
1216
FFFF
2
2
2
1.5
1.5
1.5
1
1
1
0.533
0.592
0.592
120
120
120
0
0
0
2
2
2
10
10
100
0.533
0.592
0.592
2A0211
2A0250
ND
HD
1
0
74
75
55
55
0.490
0.49
7
1
190
190
1.43
1.43
45.6
45.6
0.022
0.022
20.5
20.5
960
960
1214
1215
2
2
1.3
1.3
1
1
0.317
0.317
125
115
0
0
2
2
10
10
0.317
0.317
2A0360
2A0415
ND
HD
1
0
77
78
110
110
80
80
0.7
0.7
0.5
0.5
2.00
2.00
18.12
18.12
1.90
1.90
7
1
260
260
1.39
1.39
72
72
0.023
0.023
20
20
1200
1200
FFFF
FFFF
2
2
1.7
1.7
1
1
0.646
0.646
120
120
0
0
2
2
100
100
0.646
0.646
ND
1
75
0.90
7
260
1.39
72
0.023
20
1200
1215
2
1.5
1
0.533
115
0
2
10
0.533
ND
1
110
80
0.7
0.5
2.00
18.12
1.90
7
260
1.39
72
0.023
20
1200
FFFF
2
1.7
1
0.646
120
0
2
100
0.646
B
525

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents