Fuel; 2 Max/Coefficient; Rel/Co - TESTO 300 XXL Instruction Manual

Hide thumbs Also See for 300 XXL:
Table of Contents

Advertisement

Zeroing phase
3 sec
"Select Light oil"
Zeroing phase
or
Measurement menu

Fuel

E
:
XAMPLE
Set "Light oil"
1 Connect analyser box to control unit; switch on control
unit.
2 During the zeroing phase, the menu
"Select fuel" is automatically activated.
3 Select "Light oil" with keys
4 With key
measurement menu.
O2 reference, CO2max and coefficient
Available fuels and their factors
Fuel
Fuel oil, light
Fuel oil, heavy
Natural gas
Propane
Anthracite
Coal briquettes
Wood fuels, coke
Brown coal, peat
Coking gas
Urban gas
Fuel 1
Fuel 2
* These factory adjusted values can be freely selected.
A2, B
fuel-specific factors
conversion factor mg/m
F
Br
The O2 reference index, CO2 max. and all factors for freely
defined fuels.
The coefficients A2, B are only adjustable for the freely
definable fuels "Fuel 1 and 2". "Coeff" appears in the menu
when "Fuel 1 or 2" is selected.
Main menu Input
return to the zeroing phase or the
A2
B
f
CO
0.68 0.007 0.68
0.61
-
0.61
0.66 0.009 0.66
0.63 0.008 0.63
0,74
-
0.74
0,75
-
0.75
0.74
-
0.74
0.90
-
0.90
0.60 0.011 0.60
0.63 0.011 0.63
0*
0*
0*
0*
3
in g/GJ
for analyser box
.
*
O
ref.*
2max
2
15.4*
3*
0.2637
15.9*
3*
0.2616
11.9*
3*
0.2665
13.7*
3*
0.2613
20.5*
8*
0.2640
18.9*
8*
0.2748
20.3*
13*
0.1885
19.8*
8*
0.2647
10.3*
3*
0.2461
13.6*
3*
0.2418
0*
0*
0*
0*
F
Br
0*
0*
77