Using The Modular Fl Ue Gas Probe; Confi Guring The Reading Display; Set Location/Fuel - TESTO 340 Instruction Manual

Flue gas analyser
Hide thumbs Also See for 340:
Table of Contents

Advertisement

G.1.2 Using the modular fl ue gas probe
Checking the thermocouple
Aligning the fl ue gas probe
G.1.3 Confi guring the reading display
Only those parameters and units which are activated in the reading display appear in the
reading display, the saved measurement protocols and the protocol printouts.
G.1.4 Set location/fuel
Before carrying out measurements, the measurement location and the fuel must be cor-
rectly selected see Memory, p. 22 and Fuels, p. 35.
information@ITM.com
RGS
Before beginning measurements, confi gure the reading display so that the required
parameters and units are activated, see Display edit, p. 27.
www.
The thermocouple of the fl ue gas probe must not lie
against the probe cage.
Check before use. Bend the thermocouple back if
necessary.
The fl ue gas must be able to fl ow freely past the
thermo couple.
Align the probe by turning it as required.
The tip of the probe must be in the centre of the fl ue
gas fl ow.
Align the fl ue gas probe in the fl ue gas duct so that
the tip is in the centre of the fl ow (area of the
highest fl ue gas temperature).