Principal safety information

Use the device only in the operating and
measuring ranges specified in "Technical data".
Use the device only under the conditions and for
the purpose for which it was designed. For this,
particularly observe the safety information and the
technical data.
To prevent damage to the instrumentation and
items under test, suitably trained persons should
only use the equipment.
Observe all local Health and Safety regulations
before operating the test equipment.
Do not make measurements on live components.
Observe the warnings on the control unit and
analyser box!
Magnets of the control unit
The magnets of the control unit can damage EC
cards, telephone cards etc.
Operation with mains adapter
Use only the original mains adapter to operate the
device. Replace damaged mains cable only with
an original mains cable of the manufacturer or
agent (i.e. by authorised service).
Check for leaks
The entire measuring system (probe, condensation
trap, filter, hoses and connections) must be
checked for leaks before each measurement, e.g.
by pushing on a collapsed rubber bladder.
Measuring errors can be caused if external air
infiltrates.
Expose the gas outlet
When measuring, ensure that the gas outlets are
exposed to allow the gas to escape unobstructed.
If this is not the case, the measurement results
can be falsified.
Empty the condensation trap
The condensation trap must only be emptied when
the pump is switched off (the measuring cells are
otherwise in danger of damage)!
8
Disposing of batteries
The end user is legally required to dispose of all
used batteries in accordance with their country's
regulations.
Disposing of measuring cells
Storing the analyser in rooms containing solvents,
vapours or gases will damage the measurement
cells e.g. cleaning fluids, polishes, paints, cooking
operations. Protect the device from direct sunlight
and store at temperatures <45°C.
Storing the device
Storing the analyser in rooms containing solvents,
vapours or gases will damage the measurement
cells e.g. cleaning fluids, polishes, paints, cooking
operations. Protect the device from direct sunlight
and store at temperatures <45°C.
Charge the battery before use
Before making the first measurement or after
several days of disuse, fully charge the internal
battery (see menu Service
Operating values). Charge the battery at least
every 4 weeks during longer periods of disuse to
prevent damagingly low discharging.
Changing the configuration
Switch off the device to change the configuration
(e.g. probe change), as the device reads the
probe-specific values when it is switched on.
PC cable connected
When the PC cable is connected, it is impossible
to issue a print command.
Using probes with plug head
Ensure the good contact of probes with plug
heads. Fully tighten the union nut on the probe
handle.
Opening the device
If the device is opened, misused or subjected to
force, the warranty will be voided.
Because the pressure sensor heats up, it is
recommended to wait on the "Warm up" for 15
minutes to achieve the best possible accuracy.